| P0A1B-00 | PDU microcomputer malfunction | Refer to Electric Motor Control Unit (EMCU) and Motor (Electric Motor Unit) – Diagnostic Trouble Code Chart DIAGNOSTIC TROUBLE CODE CHART . |
| P0A2B-00 | Front drive motor coil temp. sensor 1 Rationality-correlation |
| P0A2C-00 | Front drive motor coil temperature sensor 1 Range check-min |
| P0A2D-00 | Front drive motor coil temperature sensor 1 Range check-max |
| P0A2F-00 | Front drive motor coil1 temperature-high |
| P0A37-00 | Generator coil temperature sensor Rationality-correlation |
| P0A38-00 | Generator coil temperature sensor Range check-min |
| P0A39-00 | Generator coil temperature sensor Range check-max |
| P0A3B-00 | Generator coil temperature-high |
| P0A3C-00 | FMCU Phase IGBT1 temperature-high |
| P0A3E-00 | GCU Phase IGBT1 temperature-high |
| P0A3F-00 | Front drive motor position sensor malfunction 1 |
| P0A40-00 | Front drive motor position sensor malfunction 6 |
| P0A44-00 | Front drive motor over speed |
| P0A4B-00 | Generator position sensor malfunction 1 |
| P0A4C-00 | Generator position sensor malfunction 6 |
| P0A50-00 | Generator over speed |
| P0A90-00 | Front drive motor demagnetization |
| P0A92-00 | Generator demagnetization |
| P0AEE-00 | FMCU Phase IGBT temperature sensor 1 Rationality-correlation |
| P0AEF-00 | FMCU Phase IGBT temperature sensor 1 Range check-min |
| P0AF0-00 | FMCU Phase IGBT temperature sensor 1 Range check-max |
| P0AF3-00 | FMCU Phase IGBT temperature sensor 2 Rationality-correlation |
| P0AF4-00 | FMCU Phase IGBT temperature sensor 2 Range check-min |
| P0AF5-00 | FMCU Phase IGBT temperature sensor 2 Range check-max |
| P0BCD-00 | GCU Phase IGBT temperature sensor 1 Rationality-correlation |
| P0BCE-00 | GCU Phase IGBT temperature sensor 1 Range check-min |
| P0BCF-00 | GCU Phase IGBT tempurature sensor 1 Range check-max |
| P0BD2-00 | FMCU Phase IGBT temperature sensor 3 Rationality-correlation |
| P0BD3-00 | FMCU Phase IGBT temperature sensor 3 Range check-min |
| P0BD4-00 | FMCU Phase IGBT tempurature sensor 3 Range check-max |
| P0BD7-00 | FMCU Phase IGBT temperature sensor 4 Rationality-correlation |
| P0BD8-00 | FMCU Phase IGBT temperature sensor 4 Range check-min |
| P0BD9-00 | FMCU Phase IGBT tempurature sensor 4 Range check-max |
| P0BDC-00 | FMCU Phase IGBT temperature sensor 5 Rationality-correlation |
| P0BDD-00 | FMCU Phase IGBT temperature sensor 5 Range check-min |
| P0BDE-00 | FMCU Phase IGBT tempurature sensor 5 Range check-max |
| P0BE1-00 | FMCU Phase IGBT temperature sensor 6 Rationality-correlation |
| P0BE2-00 | FMCU Phase IGBT temperature sensor 6 Range check-min |
| P0BE3-00 | FMCU Phase IGBT tempurature sensor 6 Range check-max |
| P0BE6-00 | FMCU Phase U current sensor Rationality-correlation |
| P0BE7-00 | FMCU Phase U current sensor Range check-min | Refer to Electric Motor Control Unit (EMCU) and Motor (Electric Motor Unit) – Diagnostic Trouble Code Chart DIAGNOSTIC TROUBLE CODE CHART . |
| P0BE8-00 | FMCU Phase U current sensor Range check-max |
| P0BEA-00 | FMCU Phase V current sensor Range check-max |
| P0BEB-00 | FMCU Phase V current sensor Range check-min |
| P0BEC-00 | FMCU Phase V current sensor Range check-max |
| P0BEE-00 | FMCU Phase W current sensor Rationality-correlation |
| P0BEF-00 | FMCU Phase W current sensor Range check-min |
| P0BF0-00 | FMCU Phase W current sensor Range check-max |
| P0BFD-00 | FMCU current sensor 3 Phase calculation malfunction |
| P0C01-00 | Front drive motor current-high |
| P0C05-00 | Front drive motor current deviation malfunction |
| P0C52-00 | Front drive motor position sensor malfunction 3 |
| P0C53-00 | Front drive motor position sensor malfunction 2 |
| P0C5C-00 | Front drive motor position sensor malfunction 5 |
| P0C5D-00 | Front drive motor position sensor malfunction 4 |
| P0C66-00 | Generator position sensor malfunction 3 |
| P0C67-00 | Generator position sensor malfunction 2 |
| P0C6B-00 | Generator position sensor malfunction 5 |
| P0C6C-00 | Generator position sensor malfunction 4 |
| P0C79-00 | PDU V1 voltage-high |
| P0D2E-00 | PDU V1 voltage sensor Rationality-correlation |
| P0D2F-00 | PDU V1 voltage sensor Range check-min |
| P0D30-00 | PDU V1 voltage sensor Range check-max |
| P0DA4-00 | Rear drive motor voltage sensor Rationality-correlation |
| P0DF4-00 | GCU Phase IGBT temperature sensor 2 Rationality-correlation |
| P0DF5-00 | GCU Phase IGBT temperature sensor 2 Range check-min |
| P0DF6-00 | GCU Phase IGBT tempurature sensor 2 Range check-max |
| P0DF7-00 | GCU Phase IGBT temperature sensor 3 Rationality-correlation |
| P0DF8-00 | GCU Phase IGBT temperature sensor 3 Range check-min |
| P0DF9-00 | GCU Phase IGBT tempurature sensor 3 Range check-max |
| P0DFA-00 | GCU current sensor 3 Phase calculation malfunction |
| P0E01-00 | GCU Phase U current sensor Rationality-correlation |
| P0E02-00 | GCU Phase U current sensor Range check-min |
| P0E03-00 | GCU Phase U current sensor Range check-max |
| P0E05-00 | GCU Phase V current sensor Rationality-correlation |
| P0E06-00 | GCU Phase V current sensor Range check-min |
| P0E07-00 | GCU Phase V current sensor Range check-max |
| P0E09-00 | GCU Phase W current sensor Rationality-correlation |
| P0E0A-00 | GCU Phase W current sensor Range check-min |
| P0E0B-00 | GCU Phase W current sensor Range check-max |
| P0E0C-00 | Generator current deviation malfunction |
| P0E24-00 | FMCU Phase IGBT temperature sensor 7 Rationality-correlation | Refer to Electric Motor Control Unit (EMCU) and Motor (Electric Motor Unit) – Diagnostic Trouble Code Chart DIAGNOSTIC TROUBLE CODE CHART . |
| P0E25-00 | FMCU Phase IGBT temperature sensor 7 Range check-min |
| P0E26-00 | FMCU Phase IGBT tempurature sensor 7 Range check-max |
| P0E29-00 | FMCU Phase IGBT temperature sensor 8 Rationality-correlation |
| P0E2A-00 | FMCU Phase IGBT temperature sensor 8 Range check-min |
| P0E2B-00 | FMCU Phase IGBT tempurature sensor 8 Range check-max |
| P0E8D-00 | PDU V2M voltage sensor Rationality-correlation |
| P0E8E-00 | PDU V2M voltage sensor Range check-min |
| P0E8F-00 | PDU V2M voltage sensor Range check-max |
| P3005-17 | Reactor current sensor Range check-max |
| P3006-16 | Reactor current sensor Range check-min |
| P3007-1C | Reactor current sensor Rationality-correlation |
| P3008-17 | PDU V0 voltage sensor Range check-max |
| P3009-16 | PDU V0 voltage sensor Range check-min |
| P300A-1C | PDU V0 voltage sensor Rationality-correlation |
| P300B-17 | PDU V2S voltage sensor Range check-max |
| P300C-16 | PDU V2S voltage sensor Range check-min |
| P300D-1C | PDU V2S voltage sensor Rationality-correlation |
| P300E-1C | PDU V2 voltage sensor deviation malfunction |
| P3010-16 | PDU V1 voltage-low |
| P3011-16 | PDU V2M voltage-low |
| P3012-17 | PDU V2M voltage-high |
| P3013-17 | PDU V0 voltage-high |
| P3014-17 | PDU V2S voltage-high |
| P3015-1C | VCU V0 voltage control malfunction |
| P3016-16 | FMCU gate driver power supply malfunction |
| P3017-19 | FMCU IGBT current-high |
| P3018-16 | VCU gate driver power supply malfunction |
| P3019-19 | VCU IGBT current-high |
| P301A-19 | Reactor current-high |
| P301B-17 | FMCU Phase IGBT tempurature sensor 9 Range check-max |
| P301C-16 | FMCU Phase IGBT temperature sensor 9 Range check-min |
| P301D-1C | FMCU Phase IGBT temperature sensor 9 Rationality-correlation |
| P301E-17 | FMCU Phase IGBT tempurature sensor 10 Range check-max |
| P301F-16 | FMCU Phase IGBT temperature sensor 10 Range check-min |
| P3020-1C | FMCU Phase IGBT temperature sensor 10 Rationality-correlation |
| P3021-17 | FMCU Phase IGBT tempurature sensor 11 Range check-max |
| P3022-16 | FMCU Phase IGBT temperature sensor 11 Range check-min |
| P3023-1C | FMCU Phase IGBT temperature sensor 11 Rationality-correlation |
| P3024-17 | FMCU Phase IGBT tempurature sensor 12 Range check-max |
| P3025-16 | FMCU Phase IGBT temperature sensor 12 Range check-min |
| P3026-1C | FMCU Phase IGBT temperature sensor 12 Rationality-correlation |
| P3027-17 | VCU Phase IGBT tempurature sensor 1 Range check-max | Refer to Electric Motor Control Unit (EMCU) and Motor (Electric Motor Unit) – Diagnostic Trouble Code Chart DIAGNOSTIC TROUBLE CODE CHART . |
| P3028-16 | VCU Phase IGBT temperature sensor 1 Range check-min |
| P3029-1C | VCU Phase IGBT temperature sensor 1 Rationality-correlation |
| P302A-17 | VCU Phase IGBT tempurature sensor 2 Range check-max |
| P302B-16 | VCU Phase IGBT temperature sensor 2 Range check-min |
| P302C-1C | VCU Phase IGBT temperature sensor 2 Rationality-correlation |
| P302D-17 | VCU Phase IGBT tempurature sensor 3 Range check-max |
| P302E-16 | VCU Phase IGBT temperature sensor 3 Range check-min |
| P302F-1C | VCU Phase IGBT temperature sensor 3 Rationality-correlation |
| P3030-17 | VCU Phase IGBT tempurature sensor 4 Range check-max |
| P3031-16 | VCU Phase IGBT temperature sensor 4 Range check-min |
| P3032-1C | VCU Phase IGBT temperature sensor 4 Rationality-correlation |
| P3033-17 | VCU Phase IGBT tempurature sensor 5 Range check-max |
| P3034-16 | VCU Phase IGBT temperature sensor 5 Range check-min |
| P3035-1C | VCU Phase IGBT temperature sensor 5 Rationality-correlation |
| P3036-17 | VCU Phase IGBT tempurature sensor 6 Range check-max |
| P3037-16 | VCU Phase IGBT temperature sensor 6 Range check-min |
| P3038-1C | VCU Phase IGBT temperature sensor 6 Rationality-correlation |
| P3039-17 | VCU Phase IGBT tempurature sensor 7 Range check-max |
| P303A-16 | VCU Phase IGBT temperature sensor 7 Range check-min |
| P303B-1C | VCU Phase IGBT temperature sensor 7 Rationality-correlation |
| P303C-17 | VCU Phase IGBT tempurature sensor 8 Range check-max |
| P303D-16 | VCU Phase IGBT temperature sensor 8 Range check-min |
| P303E-1C | VCU Phase IGBT temperature sensor 8 Rationality-correlation |
| P303F-98 | FMCU Phase IGBT2 temperature-high |
| P3040-98 | FMCU Phase IGBT3 temperature-high |
| P3041-98 | FMCU Phase IGBT4 temperature-high |
| P3042-98 | FMCU Phase IGBT5 temperature-high |
| P3043-98 | FMCU Phase IGBT6 temperature-high |
| P3044-98 | FMCU Phase IGBT7 temperature-high |
| P3045-98 | FMCU Phase IGBT8 temperature-high |
| P3046-98 | FMCU Phase IGBT9 temperature-high |
| P3047-98 | FMCU Phase IGBT10 temperature-high |
| P3048-98 | FMCU Phase IGBT11 temperature-high |
| P3049-98 | FMCU Phase IGBT12 temperature-high |
| P304A-98 | VCU Phase IGBT1 temperature-high | Refer to Electric Motor Control Unit (EMCU) and Motor (Electric Motor Unit) – Diagnostic Trouble Code Chart DIAGNOSTIC TROUBLE CODE CHART . |
| P304B-98 | VCU Phase IGBT2 temperature-high |
| P304C-98 | VCU Phase IGBT3 temperature-high |
| P304D-98 | VCU Phase IGBT4 temperature-high |
| P304E-98 | VCU Phase IGBT5 temperature-high |
| P304F-98 | VCU Phase IGBT6 temperature-high |
| P3050-98 | VCU Phase IGBT7 temperature-high |
| P3051-98 | VCU Phase IGBT8 temperature-high |
| P3052-17 | Front drive motor coil temperature sensor 2 Range check-max |
| P3053-16 | Front drive motor coil temperature sensor 2 Range check-min |
| P3054-1C | Front drive motor coil temperature sensor 2 Rationality-correlation |
| P3055-17 | Front drive motor coil temperature sensor 3 Range check-max |
| P3056-16 | Front drive motor coil temperature sensor 3 Range check-min |
| P3057-1C | Front drive motor coil temperature sensor 3 Rationality-correlation |
| P3058-98 | Front drive motor coil2 temperature-high |
| P3059-98 | Front drive motor coil3 temperature-high |
| P305A-17 | Oil temperature sensor Range check-max |
| P305B-16 | Oil temperature sensor Range check-min |
| P305C-1C | Oil temperature sensor Rationality-correlation |
| P305D-98 | Oil temperature-high |
| P305E-17 | PDU C0 capacitor temperature sensor Range check-max |
| P305F-16 | PDU C0 capacitor temperature sensor sensor Range check-min |
| P3060-1C | PDU C0 capacitor temperature sensor sensor Rationality-correlation |
| P3061-17 | PDU C2 capacitor temperature sensor Range check-max |
| P3062-16 | PDU C2 capacitor temperature sensor sensor Range check-min |
| P3063-1C | PDU C2 capacitor temperature sensor sensor Rationality-correlation |
| P3064-98 | PDU C0 capacitor temperature-high |
| P3065-98 | PDU C2 capacitor temperature-high |
| P3066-17 | Reactor temperature sensor Range check-max |
| P3067-16 | Reactor temperature sensor Range check-min |
| P3068-1C | Reactor temperature sensor Rationality-correlation |
| P3069-98 | Reactor temperature-high |
| P306A-17 | PDU control board temperature sensor 1 Range check-max |
| P306B-16 | PDU control board temperature sensor 1 Range check-min |
| P306C-1C | PDU control board temperature sensor 1 Rationality-correlation |
| P306D-17 | PDU control board temperature sensor 2 Range check-max |
| P306E-16 | PDU control board temperature sensor 2 Range check-min |
| P306F-1C | PDU control board temperature sensor 2 Rationality-correlation |
| P3070-98 | PDU control board 1 temperature-high |
| P3071-98 | PDU control board 2 temperature-high |
| P3072-49 | PDU AD module malfunction | Refer to Electric Motor Control Unit (EMCU) and Motor (Electric Motor Unit) – Diagnostic Trouble Code Chart DIAGNOSTIC TROUBLE CODE CHART . |
| P3073-46 | PDU EEPROM malfunction |
| P3074-7E | Electric Oil Pump Stuck-ON |
| P3075-7F | Electric Oil Pump Stuck-OFF |
| P3076-7A | Oil Leak malfunction |
| P307C-04 | PDU Torque Control malfunction |
| P307D-04 | PDU GATE Shutdown circuit malfunction |
| P307F-04 | PDU system LSI communication malfunction |
| P30A1-16 | GCU gate driver power supply malfunction |
| P30A2-19 | GCU IGBT current-high |
| P30A3-19 | Generator current-high |
| P30A4-17 | GCU Phase IGBT tempurature sensor 4 Range check-max |
| P30A5-16 | GCU Phase IGBT temperature sensor 4 Range check-min |
| P30A6-1C | GCU Phase IGBT temperature sensor 4 Rationality-correlation |
| P30A7-17 | GCU Phase IGBT tempurature sensor 5 Range check-max |
| P30A8-16 | GCU Phase IGBT temperature sensor 5 Range check-min |
| P30A9-1C | GCU Phase IGBT temperature sensor 5 Rationality-correlation |
| P30AA-17 | GCU Phase IGBT tempurature sensor 6 Range check-max |
| P30AB-16 | GCU Phase IGBT temperature sensor 6 Range check-min |
| P30AC-1C | GCU Phase IGBT temperature sensor 6 Rationality-correlation |
| P30AD-98 | GCU Phase IGBT2 temperature-high |
| P30AE-98 | GCU Phase IGBT3 temperature-high |
| P30AF-98 | GCU Phase IGBT4 temperature-high |
| P30B0-98 | GCU Phase IGBT5 temperature-high |
| P30B1-98 | GCU Phase IGBT6 temperature-high |
| U1E30-08 | LIN Communication malfunction |
| U1E31-08 | LIN Communication malfunction with EOP |
| U1E33-87 | PDU Lost Communication with PHEV-ECU |
| U1E34-87 | PDU Lost Communication with BMS |
| U1E35-87 | PDU Lost Communication with OBC |
| U1E36-87 | PDU Lost Communication with RMCU |
| U1E37-83 | PDU Communication error with PHEV-ECU |
| U1E38-83 | PDU Communication error with BMS |