(1) Measure the selector lever connector side by backprobing.
(2) Change the power supply mode of the electric motor switch to ON (READY indicator: OFF).
(3) Measure the voltage between the selector lever connector (SF06 terminal) and body ground.
Check condition | Normal condition |
Selector lever: H, Nd | 1.6 ± 0.5 V |
other than above | 2.98 ± 0.3 V |
Is the check result normal?