When servicing the junction box, On Board Charger (OBC)/DC-DC converter, and AC inverter, disconnect the rear interlock connector in addition to the service plug removal to secure the safety (Refer to PRECAUTIONS ON HOW TO USE THE HIGH-VOLTAGE VEHICLE).
MONITOR EXECUTION
Continuous
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Not applicable
Sensor (The sensor below is determined to be normal)
Not applicable
DTC SET CONDITIONS
Logic Flow Chart
Check Condition
Drive battery precharge contactor control circuit activation command: ON
Drive battery positive contactor control circuit activation command: OFF
Drive battery negaitive contactor control circuit activation command: OFF
EV power source relay drive signal: ON
Judgment Criterion
The change of the input voltage of the power drive unit is more than 60 volts for 0.4 second or more.
The change of the input voltage of the REMCU is more than 60 volts for 0.4 second or more.
The trouble can be an intermittent malfunction (Refer to General Information - How to Use Troubleshooting/Inspection Service Points, How to Cope with Intermittent Malfunctions HOW TO COPE WITH INTERMITTENT MALFUNCTIONS).
4.AC inverter check
danger
Carry out the check on the high voltage circuit while reading carefully the precautions on handling a high voltage vehicle.
Be sure to wear the specified protective equipment when checking the high voltage circuit.
(1) Disconnect the high voltage cable between the junction box and AC inverter.
(2) Carry out a test drive with the drive cycle pattern. Refer to OBD-II Drive Cycle OBD-II DRIVE CYCLE.