1.STEP 1. Using scan tool (M.U.T.-III SE), read the DTC.
Use scan tool (M.U.T.-III SE) to check and see if a DTC P24BE-00, P24BF-00, P24D7-00 or P24D8-00 is set.Q: Is DTC P24BE-00, P24BF-00, P24D7-00 or P24D8-00 set?
2.STEP 2. Check of damage in wiring harness between ELCM connector terminal number 4 and ECM connector terminal number 80.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
3.STEP 3. Check of damage in wiring harness between ELCM connector terminal number 7 and ECM connector terminal number 97.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
4.STEP 4. Check of damage in wiring harness between ELCM connector terminal number 6 and ECM connector terminal number 107.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
5.STEP 5. Check of damage in wiring harness between ELCM connector terminal number 5 and ECM connector terminal number 117.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
6.STEP 6. Check of damage in wiring harness between IPDM E/R (with built-in MFI relay) connector terminal number 78 and ELCM connector terminal number 8.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
7.STEP 7. Check of short circuit, open circuit or damage in wiring harness between ELCM connector terminal number 2 and ECM connector terminal number 93.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
8.STEP 8. Check of open circuit and damage in ground line between ELCM connector terminal number 1 and ground.
Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
9.STEP 9. Using scan tool (M.U.T.-III SE) to check the data list, after replace ELCM and perform the evaporative emission system monitor test.
(3) Use scan tool (M.U.T.-III SE) to check the data list (Refer to DATA LIST REFERENCE TABLE).- Item number 470: Vent Valve Stuck Closed or Pump
Q: Is the check result normal?
The inspection is complete.