CIRCUIT OPERATION
- Switching valve is built into the Evaporative Leak Check Module (ELCM).
- MFI relay is built into the IPDM E/R.
- The switching valve power is supplied from the MFI relay.
- The ECM controls switching valve by turning the power transistor in the ECM "ON" and "OFF".
TECHNICAL DESCRIPTION
In response to a signal from the ECM, the switching valve switches the atmospheric side path of the evaporative emission canister to the reference path for the evaporative emission system leak monitor.
MONITOR EXECUTION
Continuous.
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
DTC SET CONDITIONS
Check Conditions
- Power supply mode of electric motor switch is ON.
- 12V battery positive voltage is between 10.0 and 16.5 volts.
Judgment Criterion
- The coil current is 2 amperes or higher with the switching valve driving for 2 seconds.
FAIL-SAFE AND BACKUP FUNCTION
- Prohibit introduction of purges.
- Fuel filler lid cannot be opened even when pressing the fuel filler lid opener switch.
- Indicates "REFUELING SYSTEM SERVICE REQUIRED" on the information screen in the multi-information display.
OBD-II DRIVE CYCLE PATTERN
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)
- Switching valve (built into the ELCM) failed.
- Shorted switching valve circuit, harness damage or connector damage.
- ECM failed.