1.STEP 1. Using scan tool (M.U.T.-IIISE), perform the actuator test.
Use scan tool (M.U.T.-III SE) to perform the actuator test (Refer to ACTUATOR TEST REFERENCE TABLE).- Item number 30: Purge Control Solenoid Valve
OK: Operating sound can be heard and the valve vibrates
Q: Is the check result normal?
2.STEP 2. Check evaporative emission purge solenoid itself.
Check evaporative emission purge solenoid itself (Refer to ENGINE, Engine, Motor and Emission Control – Emission Control – Evaporative Emission System EVAPORATIVE EMISSION PURGE SOLENOID CHECK).Q: Is the check result normal?
3.STEP 3. Perform voltage measurement at evaporative emission purge solenoid connector terminal number 2.
- Disconnect connector, and measure at harness side.
- Power supply mode of electric motor switch: ON
- Voltage between evaporative emission purge solenoid connector terminal number 2 and ground.
OK: 12V battery positive voltage
Q: Is the check result normal?
Repair or replace the connector, or check and repair harness between IPDM E/R connector terminal number 66 and evaporative emission purge solenoid connector terminal number 2.
4.STEP 4. Perform voltage measurement at ECM connector terminal number 14.
- Disconnect connector, and measure at harness side.
- Power supply mode of electric motor switch: ON
- Voltage between ECM connectors terminal number 14 and ground.
OK: 12V battery positive voltage
Q: Is the check result normal?
Repair or replace the connector, or check and repair harness between ECM connector terminal number 14 and evaporative emission purge solenoid connector terminal number 1.
5.STEP 5. Check harness between evaporative emission purge solenoid connector terminal number 1 and ECM connector terminal number 14.
Check output line for damage.Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
6.STEP 6. Check harness between IPDM E/R connector terminal number 66 and evaporative emission purge solenoid connector terminal number 2.
Check power supply line for damage.Q: Is the check result normal?
Repair or replace the connector, or repair the damaged harness wire.
7.STEP 7. Using scan tool (M.U.T.-IIISE), perform the actuator test.
Use scan tool (M.U.T.-III SE) to perform the actuator test (Refer to ACTUATOR TEST REFERENCE TABLE).- Item number 30: Purge Control Solenoid Valve
OK: Operating sound can be heard and the valve vibrates
Q: Is the check result normal?
8.STEP 8. Test the OBD-II drive cycle.
After erasing the DTC, carry out test drive with the drive cycle pattern, and recheck the DTC.(1) Use scan tool (M.U.T.-III SE) to erase the DTC.
(2) Carry out test drive with the drive cycle pattern (Refer to Diagnostic Function, OBD-II Drive Cycle – Pattern 1 OBD- II DRIVE CYCLE). (3) Use scan tool (M.U.T.-III SE) to recheck the DTC.
Q: Is DTC P0458-00 set?
Intermittent malfunction (Refer to GENERAL INFORMATION, General Information – How to Use Troubleshooting/Inspection Service Points – How to Cope with Intermittent Malfunctions HOW TO COPE WITH INTERMITTENT MALFUNCTIONS).