Injection cut | 10 | Fuel injector | Specified fuel injector is stopped. | Continuous idling mode (cut the fuel supply to each injector in turn and check cylinders which don't affect idling), | Idle condition is changed by stopping selected cylinder: this can cause an unstable condition and the engine may stall. |
Fuel Pump | 20 | Fuel tank pump | Fuel tank pump operates and fuel is recirculated. | - Power supply mode of electric motor switch: ON
- Listen near the fuel tank for the sound of fuel tank pump operation.
| Sound of operation is heard. |
Purge Control Solenoid Valve | 30 | Evaporative emission purge solenoid | Solenoid valve turns from OFF to ON. | Power supply mode of electric motor switch: ON | Clicks when solenoid valve is driven. |
IG 5 BTDC | 40 | Basic ignition timing | Set to ignition timing adjustment mode. | - Engine: Continuous idling mode
- If the BMU data list item number 35: SOC CAN Output, charge state (control) is less than 35 percent, charge so that the charge state (control) can become 35 percent or more [Refer to Electric Power Train, Battery Management Unit (BMU) and Traction Battery – Troubleshooting DATA LIST REFERENCE TABLE]
- Connect timing light (Refer to Engine, Engine Mechanical – On-vehicle Service IGNITION TIMING CHECK)
| 5°BTDC ± 3° |
Cooling fan | 50 | Radiator fan motor | Drive the fan motor. | Power supply mode of electric motor switch: ON | The radiator fan motors (LH and RH) rotate rapidly. |
Oil control valve | 60 | Oil feeder control valve | Switch the oil feeder control valve from OFF to ON | Power supply mode of electric motor switch: ON | When the valve is actuated, operating noise is audible. |
EVAP System Bypass Solenoid Valve | 80 | Bypass valve | Bypass valve turns from OFF to ON. | - Power supply mode of electric motor switch: ON (not READY)
- It is not in the evaporative emission system monitor test.
- It is not in the refuel control mode.
- Listen near the evaporative emission canister (main) for the sound of bypass valve operation.
| - Clicks when solenoid valve is driven.
- Data list item number 660: EVAP System Bypass Solenoid is displayed "ON".
|
Bypass valve turns OFF. | - Operating sound cannot be heard.
- Data list item number 660: EVAP System Bypass Solenoid is displayed "OFF".
|
EVAP System Vent Valve | 90 | Switching valve | Switching valve turns from OFF to ON. | - Power supply mode of electric motor switch: ON (not READY)
- It is not in the evaporative emission system monitor test.
- It is not in the refuel control mode.
- Listen near the evaporative leak check module (ELCM) for the sound of switching valve operation.
| - Clicks when solenoid valve is driven.
- Data list item number 650: EVAP System Vent Valve is displayed "ON".
|
Switching valve turns OFF. | - Operating sound cannot be heard.
- Data list item number 650: EVAP System Vent Valve is displayed "OFF".
|
EVAP system sealing valve | 100 | Fuel tank solenoid valve | Fuel tank solenoid valve turns from OFF to ON. | - Power supply mode of electric motor switch: ON (not READY)
- It is not in the evaporative emission system monitor test.
- It is not in the refuel control mode.
- Listen near the fuel tank for the sound of fuel tank solenoid valve operation.
| - Clicks when solenoid valve is driven.
- The fuel tank differential pressure sensor output is coming near the atmospheric pressure.
- Data list item number 640: EVAP System Switching Valve is displayed "ON".
|
Fuel tank solenoid valve turns OFF. | - Operating sound cannot be heard.
- Data list item number 640: EVAP System Switching Valve is displayed "OFF".
|
EVAP System Leak Detection Pump | 110 | Evaporative emission leak detection pump | Evaporative emission leak detection pump operates. | - Power supply mode of electric motor switch: ON (not READY)
- It is not in the evaporative emission system monitor test.
- It is not in the refuel control mode.
- Listen near the ELCM for the sound of evaporative emission leak detection pump operation.
| - Operating sound can be heard.
- Data list item number 630: EVAP System Leak Detection Pump control is displayed "ON".
|
Evaporative emission leak detection pump stops. | - Operating sound cannot be heard.
- Data list item number 630: EVAP System Leak Detection Pump control is displayed "OFF".
|
Fuel Filler Door Motor Relay | 120 | Fuel filler lid opener relay | Fuel filler lid opener relay turns from OFF to ON. | - Power supply mode of electric motor switch: ON (not READY)
- The fuel filler lid opener relay is not in operation.
| - Fuel filler lid opens*.
- Data list item number 620: Fuel Fill Door Motor relay is displayed "ON".
|
Fuel filler lid opener relay turns OFF. | - Operating sound of fuel filler lid opener actuator cannot be heard.
- Data list item number 620: Fuel Fill Door Motor relay is displayed "OFF".
|