[Previous][Next]
ACTUATOR TEST REFERENCE TABLE
M.U.T.-III SE SCAN TOOL DISPLAYITEM NO.INSPECTION ITEMDRIVE CONTENTSINSPECTION REQUIREMENTNORMAL CONDITION
Injection cut10Fuel injectorSpecified fuel injector is stopped.Continuous idling mode (cut the fuel supply to each injector in turn and check cylinders which don't affect idling),Idle condition is changed by stopping selected cylinder: this can cause an unstable condition and the engine may stall.
Fuel Pump20Fuel tank pumpFuel tank pump operates and fuel is recirculated.
  • Power supply mode of electric motor switch: ON
  • Listen near the fuel tank for the sound of fuel tank pump operation.
Sound of operation is heard.
Purge Control Solenoid Valve30Evaporative emission purge solenoidSolenoid valve turns from OFF to ON.Power supply mode of electric motor switch: ONClicks when solenoid valve is driven.
IG 5 BTDC40Basic ignition timingSet to ignition timing adjustment mode.
  • Engine: Continuous idling mode
  • If the BMU data list item number 35: SOC CAN Output, charge state (control) is less than 35 percent, charge so that the charge state (control) can become 35 percent or more [Refer to Electric Power Train, Battery Management Unit (BMU) and Traction Battery – Troubleshooting DATA LIST REFERENCE TABLE]
  • Connect timing light (Refer to Engine, Engine Mechanical – On-vehicle Service IGNITION TIMING CHECK)
5°BTDC ± 3°
Cooling fan50Radiator fan motorDrive the fan motor.Power supply mode of electric motor switch: ONThe radiator fan motors (LH and RH) rotate rapidly.
Oil control valve60Oil feeder control valve Switch the oil feeder control valve from OFF to ONPower supply mode of electric motor switch: ONWhen the valve is actuated, operating noise is audible.
EVAP System Bypass Solenoid Valve80Bypass valveBypass valve turns from OFF to ON.
  • Power supply mode of electric motor switch: ON (not READY)
  • It is not in the evaporative emission system monitor test.
  • It is not in the refuel control mode.
  • Listen near the evaporative emission canister (main) for the sound of bypass valve operation.
  • Clicks when solenoid valve is driven.
  • Data list item number 660: EVAP System Bypass Solenoid is displayed "ON".
Bypass valve turns OFF.
  • Operating sound cannot be heard.
  • Data list item number 660: EVAP System Bypass Solenoid is displayed "OFF".
EVAP System Vent Valve90Switching valveSwitching valve turns from OFF to ON.
  • Power supply mode of electric motor switch: ON (not READY)
  • It is not in the evaporative emission system monitor test.
  • It is not in the refuel control mode.
  • Listen near the evaporative leak check module (ELCM) for the sound of switching valve operation.
  • Clicks when solenoid valve is driven.
  • Data list item number 650: EVAP System Vent Valve is displayed "ON".
Switching valve turns OFF.
  • Operating sound cannot be heard.
  • Data list item number 650: EVAP System Vent Valve is displayed "OFF".
EVAP system sealing valve100Fuel tank solenoid valveFuel tank solenoid valve turns from OFF to ON.
  • Power supply mode of electric motor switch: ON (not READY)
  • It is not in the evaporative emission system monitor test.
  • It is not in the refuel control mode.
  • Listen near the fuel tank for the sound of fuel tank solenoid valve operation.
  • Clicks when solenoid valve is driven.
  • The fuel tank differential pressure sensor output is coming near the atmospheric pressure.
  • Data list item number 640: EVAP System Switching Valve is displayed "ON".
Fuel tank solenoid valve turns OFF.
  • Operating sound cannot be heard.
  • Data list item number 640: EVAP System Switching Valve is displayed "OFF".
EVAP System Leak Detection Pump 110Evaporative emission leak detection pumpEvaporative emission leak detection pump operates.
  • Power supply mode of electric motor switch: ON (not READY)
  • It is not in the evaporative emission system monitor test.
  • It is not in the refuel control mode.
  • Listen near the ELCM for the sound of evaporative emission leak detection pump operation.
  • Operating sound can be heard.
  • Data list item number 630: EVAP System Leak Detection Pump control is displayed "ON".
Evaporative emission leak detection pump stops.
  • Operating sound cannot be heard.
  • Data list item number 630: EVAP System Leak Detection Pump control is displayed "OFF".
Fuel Filler Door Motor Relay120Fuel filler lid opener relayFuel filler lid opener relay turns from OFF to ON.
  • Power supply mode of electric motor switch: ON (not READY)
  • The fuel filler lid opener relay is not in operation.
  • Fuel filler lid opens*.
  • Data list item number 620: Fuel Fill Door Motor relay is displayed "ON".
Fuel filler lid opener relay turns OFF.
  • Operating sound of fuel filler lid opener actuator cannot be heard.
  • Data list item number 620: Fuel Fill Door Motor relay is displayed "OFF".
note*: When the fuel filler lid is opened, the fueling control mode is activated. To deactivate the fueling control mode, perform the following operations.
  • After the operation, leave the vehicle for 30 minutes.
  • Drive the vehicle for approximately 30 seconds continuously.