CHECK ON INSULATION RESISTANCE OF AC INVERTER
danger
cautionThe insulation resistance check must be completed within 10 seconds. (Since DC 1,000 V is applied while checking, parts may be damaged if the check continues for 10 seconds or more.)
Required Special Tools:
  • MB991223: Wiring harness set
  • MB992006: Extra fine probe
  • MB992355: Electric insulation tester
1. Remove the third seat (Refer to Removal and Installation).
2. Remove the cargo floor cover (Refer to Removal and Installation).
3. Remove the EV control unit cover (LH/RH) (Refer to ON BOARD CHARGER (OBC) &DC-DC CONVERTER REMOVAL AND INSTALLATION).
4. Disconnect the high voltage cable (P, N) from the AC inverter.
5. Disconnect the AC power supply wiring harness from the AC inverter.
6. Use the electric insulation tester (Special tool: MB992355) and set it to the 1,000 V range.
7. Measure the insulation resistance between the AC inverter high voltage terminals (P, N) and AC power supply terminals (AC+, AC-), and AC inverter (body ground).
Standard value: 10 MΩ or more
8. If the measured value is not within the standard value, replace the AC inverter.