MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
- Power drive unit voltage sensor
DTC SET CONDITIONS
Check Condition A <DTC No. P0C79-00, P3012-17, P3013-17>
- Power drive unit (VCU) power supply voltage is 8.0 volts or more.
- IGBT status: ON
Judgment Criterion A <DTC No. P0C79-00, P3012-17, P3013-17>
- The voltage-high switch is in ON condition three times or more.
Check Condition B <DTC No. P0C79-00, P3012-17, P3013-17>
- Power drive unit (VCU) power supply voltage is 8.0 volts or more.
Judgment CriterionB <DTC No. P0C79-00, P3012-17, P3013-17>
- The voltage-high switch is in ON condition for 0.4 second or more.
Check Condition A <DTC No. P3014-17>
- Power drive unit (VCU) power supply voltage is 8.0 volts or more.
- IGBT status: ON
Judgment Criterion A <DTC No. P3014-17>
- The voltage-high switch is in ON condition three times or more.
Check Condition B <DTC No. P3014-17>
- Power drive unit (VCU) power supply voltage is 8.0 volts or more.
Judgment Criterion B <DTC No. P3014-17>
- The voltage-high switch is in ON condition for 0.5 second or more.