CIRCUIT OPERATION
- Intake air temperature sensor is built into the mass airflow sensor.
- Power is supplied by the ECM connector terminal number 76 to the mass airflow sensor connector terminal number 1.
- The mass airflow sensor connector terminal number 3 is grounded through the ECM connector terminal number 98.
- The sensor signal is inputted to the ECM connector terminal number 78 from the mass airflow sensor connector terminal number 2.
TECHNICAL DESCRIPTION
The intake air temperature sensor monitors the state inside the intake air temperature sensor.
DESCRIPTIONS OF MONITOR METHODS
Anomalies detected inside the sensor are transmitted to the ECM.
MONITOR EXECUTION
Continuous.
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
DTC SET CONDITIONS
Check Conditions
- More than 2 seconds have passed since the power supply mode of the electric motor switch was ON.
or
- More than 2 seconds have passed since the key-off evaporative leakage monitoring was started.
- 12V battery positive voltage is more than 10.0 volts and is less than 16.5 volts.
Judgment Criterion
- The sensor output temperature is more than 438°C (820°F) or more for 2 seconds or more.
or
- When the sensor malfunction signal (2h) is output for 2 seconds or more as a intake air temperature sensor malfunction signal.
FAIL-SAFE AND BACKUP FUNCTION
Control as if the intake air temperature is 25°C (77°F).
OBD-II DRIVE CYCLE PATTERN
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)
- Intake air temperature sensor (built into the mass airflow sensor) failed.
- ECM failed.