MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
- Rear motor coil temperature sensor <DTC No. P0A35-00, P30EF-98>
- Rear motor capacitor temperature sensor <DTC No. P30F3-98>
- REMCU temperature sensor <DTC No. P30F6-98>
DTC SET CONDITIONS
Check Condition
- REMCU power supply voltage is 8.0 volts or more.
Judgment Criterion <DTC No.P0A35-00, P30EF-98>
- The coil temperature is 177°C (350°F) or more for 1 second or more.
Judgment Criterion <DTC No.P30F3-98>
- The capacitor temperature is 103°C (217°F) or more for 1 second or more.
Judgment Criterion <DTC No.P30F6-98>
- The control module temperature is 103°C (217°F) or more for 1 second or more.