MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
- Power drive unit current sensor
DTC SET CONDITIONS
Check Condition A <DTC No. P0C01-00>
- Power drive unit (FEMCU) power supply voltage is 8.0 volts or more.
- IGBT status: ON
Judgment Criterion A <DTC No. P0C01-00>
- The drive motor current-high switch is in ON condition three times or more.
Check Condition B <DTC No. P0C01-00>
- Power drive unit (FEMCU) power supply voltage is 8.0 volts or more.
Judgment Criterion B <DTC No. P0C01-00>
- The drive motor current-high switch is in ON condition for 0.4 second or more.
Check Condition A <DTC No. P0C05-00>
- Power drive unit (FEMCU) power supply voltage is 8.0 volts or more.
- The phase current order is 60 amperes or more.
- The front motor speed is more than 400 rpm.
Judgment Criterion A <DTC No. P0C05-00>
- The U/V/W phase current is between -32.8 amperes and 32.8 amperes for 0.40 second or more.
- The U/V/W phase current is -32.8 amperes or more for 0.40 second or more.
- The U/V/W phase current is 32.8 amperes or less for 0.40 second or more.
Check Condition B <DTC No. P0C05-00>
- Power drive unit (FEMCU) power supply voltage is 8.0 volts or more.
- The phase current order is 60 amperes or more.
- The front motor speed is less than 3,000 rpm.
Judgment Criterion B <DTC No. P0C05-00>
- The difference between the U/V/W phase current and U/V/W phase target current is in fail condition for 0.40 second or more.