CIRCUIT OPERATION
- The sensor signal is inputted to the ECM connector terminal number 49 from the heated oxygen sensor (rear) connector terminal number 4.
- The heated oxygen sensor (rear) connector terminal number 3 is grounded with ECM connector terminal number 50.
- The ECM connector terminal number 50 applies an offset voltage of 0.5 volt to the heated oxygen sensor (rear) connector terminal number 3.
TECHNICAL DESCRIPTION
- The ECM applies an offset voltage of 0.5 volt to the heated oxygen sensor (rear).
- The ECM checks for heated oxygen sensor (rear) offset voltage.
DESCRIPTIONS OF MONITOR METHODS
Heated oxygen sensor (rear) offset voltage is over specified range.
MONITOR EXECUTION
Continuous.
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
DTC SET CONDITION
Check Condition
- More than 2 seconds have passed since the power supply mode of the electric motor switch was ON.
Judgment Criterion
- Heated oxygen sensor (rear) offset voltage is higher than 0.6 volt for 2 seconds.
FAIL-SAFE AND BACKUP FUNCTION
Does not control air-fuel ratio closed loop.
OBD-II DRIVE CYCLE PATTERN
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)
- Heated oxygen sensor (rear) failed.
- Shorted heated oxygen sensor (rear) circuit or connector damage.
- ECM failed.