CIRCUIT OPERATION
- A power voltage of 5 volts is applied to the knock sensor connector terminal number 2 from the ECM connector terminal number 59.
- The power voltage is grounded to the ECM connector terminal number 60 from the knock sensor connector terminal number 1.
TECHNICAL DESCRIPTION
- The knock sensor converts the vibration of the cylinder block into a voltage and outputs it.
- The ECM checks whether the voltage is within a specified range.
DESCRIPTIONS OF MONITOR METHODS
Knock sensor output voltage is out of specified range.
MONITOR EXECUTION
Continuous.
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
DTC SET CONDITIONS
Check Condition
- More than 2 seconds have passed since the power supply mode of the electric motor switch was ON.
Judgment Criterion
- Knock sensor output voltage has continued to be lower than 0.5 volt for 2 seconds.
FAIL-SAFE AND BACKUP FUNCTION
Fix the ignition timing with an allowance against knock.
OBD-II DRIVE CYCLE PATTERN
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)
- Knock sensor failed.
- Open or shorted knock sensor circuit, harness damage or connector damage.
- ECM failed.