DTC P1D30: Low Temperature Abnormal
 
 
 
 
TROUBLE JUDGMENT
Check Condition
  • While the on board charger is allowed to charge from PHEV-ECU.
Judgment Criterion
  • The internal ambient temperature sensor detects the extremely low temperature.
or
  • The temperature sensor of the power factor correction circuit detects the extremely low temperature.
or
  • The inverter temperature sensor 1 detects the extremely low temperature.
or
  • The inverter temperature sensor 2 detects the extremely low temperature.
 
 
 
FAIL-SAFE AND BACKUP FUNCTION
  • The charge is stopped.
 
 
PROBABLE CAUSES
  • The ambient temperature is extremely low.
  • The on board charger/DC-DC converter is failed.
 
 
 
 
DIAGNOSIS
Required Special Tools
  • MB991223: Wiring harness set
  • MB992006: Extra fine probe
STEP 1. Using scan tool (M.U.T.-IIISE), check on board charger/DC-DC converter data list.
  • Data List Reference Table (Refer to ).
    • Item No.38: PFC temperature
    • Item No.39: Inverter temperature 1
    • Item No.40: Inverter temperature 2
    • Item No.41: Inside temperature
Are the check result normal?
Go to Step 2.
Replace the on board charger/DC-DC converter (Refer to ).
 
STEP 2. Using scan tool (M.U.T.-IIISE), check whether the DTC is set again.
Is the DTC set?
Replace the on board charger/DC-DC converter (Refer to ).
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).