[Previous][Next]
DATA LIST REFERENCE TABLE
 
 
Item No.Inspection itemInspection conditionsValue to be determined as normal
1*Accumulated CHG count for 100VPower supply mode of electric motor switch: ACCAccumulated number (times) of charging by 100 volts system power supply
2Accumulated CHG count for 200VPower supply mode of electric motor switch: ACCAccumulated number (times) of charging by 200 volts system power supply
3*Accumulated CHG time for 100VPower supply mode of electric motor switch: ACCAccumulated charging time (min) by 100 volts system power supply
4Accumulated CHG time for 200VPower supply mode of electric motor switch: ACCAccumulated charging time (min) by 200 volts system power supply
5Current charge timePower supply mode of electric motor switch: ACCPrevious charging time (min)
6Accumulated CHG fail stop countPower supply mode of electric motor switch: ACCAccumulated number (times) of abnormal stop during charging
7DCDC accumulated active countPower supply mode of electric motor switch: ACCAccumulated number (times) of DC-DC converter operation
8DCDC accumulated active timePower supply mode of electric motor switch: ACCAccumulated operating time (min) of DC-DC converter
9Current DCDC active timeDuring normal chargingOperating time (min) of DC-DC converter at this time
10DCDC accumulated fail stop countDuring normal chargingAccumulated number (times) of abnormal stop during DC-DC converter operation
11On board CHG permit (CAN) flagDuring normal chargingON or OFF
13Charge flagDuring normal chargingON or OFF
14Abnormal stop flagDuring normal chargingON or OFF
15EEPROM write statusDuring normal chargingChange depending on charging status ("Complete" or "Now writing")
16S2 switchPower supply mode of electric motor switch: ONOFF
During normal chargingON
17Cooling request flagDuring normal chargingON or OFF
18Control power supply req. flagDuring normal chargingON or OFF
19PFC start-up flagDuring normal chargingON or OFF
20Input current 0 point checkDuring normal chargingChange depending on charging status ("Not accept" or "Accept")
21Output limit his.(Input volt)During normal chargingChange depending on charging status ("No record", "Recorded", "N/A" or "Executing")
22Output limit his. (TEMP. trigger)During normal chargingChange depending on charging status ("No record", "Recorded", "N/A" or "Executing")
23Current input voltage typeDuring normal chargingChange depending on charging status ("No input", "100 volts" or "200 volts")
24Control modeDuring normal chargingChange depending on charging status ("No input", "Idling", "Charge start", "Charging", "Charge end", "EEPROM" or "Error")
25Output limit flagDuring normal chargingON or OFF
26Output limit judge (TEMP.)During normal chargingON or OFF
27Output limit judge (Input volt.)During normal chargingON or OFF
29Input voltagePower supply mode of electric motor switch: ACC0 volt
  • Power supply mode of electric motor switch: ACC
  • Perform normal charging
90 V - 254 V
30Input currentPower supply mode of electric motor switch: ACC0 A
  • Power supply mode of electric motor switch: OFF
  • During normal charging
15 A or less
31Output voltage
  • Power supply mode of electric motor switch: OFF
  • During normal charging
180 V - 370 V
32Output current
  • Power supply mode of electric motor switch: OFF
  • Perform normal charging.
13.5 A or less
33Voltage target valueDuring normal chargingTarget voltage (V) of PHEV-ECU
34Current target valueDuring normal chargingTarget current (A) of PHEV-ECU
35Power supply voltagePower supply mode of electric motor switch: ACCSystem voltage
36PFC output voltage
  • Power supply mode of electric motor switch: OFF
  • During normal charging
140 - 350 V
37Pilot signal (Duty ratio)
  • Power supply mode of electric motor switch: OFF
  • During normal charging
Charging cable not connected0 % or 100 %
Charging cable connected8 - 97 %
38PFC temperature
  • Power supply mode of electric motor switch: OFF
  • During normal charging
-40 to 115 °C (-104 to 239 °F)
39Inverter temperature 1
  • Power supply mode of electric motor switch: OFF
  • During normal charging
-40 to 115 °C (-104 to 239 °F)
40Inverter temperature 2
  • Power supply mode of electric motor switch: OFF
  • During normal charging
-40 to 115 °C (-104 to 239 °F)
41Inside temperature
  • Power supply mode of electric motor switch: OFF
  • During normal charging
-40 to 115 °C (-104 to 239 °F)
42Power supply voltage(CAN)Ready indicator is illuminatedSystem voltage
43Motor/Inverter coolant TEMP.Ready indicator is illuminated-40 to 105 °C (-104 to 221 °F)
44DCDC drive permission flagReady indicator is illuminatedON or OFF
45DCDC drive flagReady indicator is illuminatedON or OFF
46DCDC fail flagReady indicator is illuminatedON or OFF
48DCDC output volt target valueReady indicator is illuminatedTarget voltage (V) of DC-DC converter
49DCDC Input voltageReady indicator is illuminated200 - 370 V
50DCDC Input currentReady indicator is illuminated0 - 12 A
51DCDC Output voltage (S terminal)Ready indicator is illuminatedSystem voltage
52DCDC Output voltage (B terminal)Ready indicator is illuminatedSystem voltage
53DCDC Output currentReady indicator is illuminated132 A or less
54DCDC power supply voltageReady indicator is illuminatedSystem voltage
55DCDC inverter temperature1Ready indicator is illuminated-40 to 105 °C (-104 to 221 °F)
56DCDC rectification temperatureReady indicator is illuminated-40 to 105 °C (-104 to 221 °F)
57DCDC inverter temperature2Ready indicator is illuminated-40 to 120 °C (-104 to 248 °F)
58DCDC power supply voltage(CAN)Ready indicator is illuminatedSystem voltage
59DCDC Motor/Inverter coolant TEMPReady indicator is illuminated-40 to 105 °C (-104 to 221 °F)
60Charge start-up req. signal (HW)Ready indicator is illuminatedLo or Hi
61Charge start-up req. signal (CAN)Ready indicator is illuminatedLo or Hi
note*: Data items are displayed on scan tool (M.U.T.-IIISE) display, but they are not used for the check.