DTC P1D33: AD Converter Abnormal
 
 
 
 
MONITOR EXECUTION
  • Continuous
 
 
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
  • Not applicable
Sensor (The sensor below is determined to be normal)
  • Not applicable
 
 
DTC SET CONDITIONS
Logic Flow Chart
Check Conditions
  • OBC power supply voltage is 10 volts to 16 volts.
Judgment Criterion
  • Status fail.
 
 
OBD-II DRIVE CYCLE PATTERN
  • Refer to OBD-II Drive Cycle - Pattern 1 .
 
 
FAIL-SAFE AND BACKUP FUNCTION
  • The charge is stopped.
 
 
PROBABLE CAUSE
  • The on board charger/DC-DC converter is failed.
 
 
 
DIAGNOSIS
STEP 1. Test the OBD-II drive cycle.
(1) Carry out a test drive with the drive cycle pattern. Refer to OBD-II Drive Cycle - Pattern 1 .
(2) Check the DTC.
Is the DTC set?
Replace the on board charger/DC-DC converter (Refer to ). Then go to Step 2.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
 
STEP 2. Test the OBD-II drive cycle.
(1) Carry out a test drive with the drive cycle pattern. Refer to OBD-II Drive Cycle - Pattern 1 .
(2) Check the DTC.
Is the DTC set?
Retry the troubleshooting.
The inspection is complete.