MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
- Battery charger control module (OBC) monitor
- EV CAN monitor
Sensor (The sensor below is determined to be normal)
Check Conditions <DTC P0D3F, P0D40>
- OBC power supply voltage is 10 volts to 16 volts.
Judgment Criterion <DTC P0D3F>
- Change of the charger input voltage sensor voltage is less than 0.474 volt (less than -517 volts) for 0.5 second.
Judgment Criterion <DTC P0D40>
- Change of the charger input voltage sensor voltage is more than 3.161 volts (more than 492 volts) for 0.5 second.