MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
- Battery charger control module (OBC) monitor
Sensor (The sensor below is determined to be normal)
Check Conditions <DTC P0D3A, P0D3B>
- OBC power supply voltage is 10 volts to 16 volts.
Judgment Criterion <DTC P0D3A>
- Change of the charger input current sensor voltage is less than 0.344 volt (less than -54 amperes) for 0.5 second.
Judgment Criterion <DTC P0D3B>
- Change of the charger input current sensor voltage is more than 4.658 volts (more than 54 amperes) for 0.5 second.