MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
DTC SET CONDITIONS
Check Conditions
- Power drive unit (GCU) power supply voltage is 8 volts to 16 volts.
Judgment Criterion <DTC P0E03, P0E0B>
- Change of the power drive unit (GCU) current sensor voltage is more than 4.7 volts (770 amperes) for 0.3 second.
Judgment Criterion <DTC P0E02, P0E0A>
- Change of the power drive unit (GCU) voltage is less than 0.3 volt (-770 amperes) for 0.3 second.
Check Conditions <DTC P0E01, P0E09>
- Power drive unit (GCU) power supply voltage is 8 volts to 16 volts.
- The IGBT status of power drive unit (GCU) is off (Shutdown) or off to on.
Judgment Criterion <DTC P0E01, P0E09>
- When the IGBT status of the power drive unit (GCU) is off (Shutdown), when a state where the power drive unit (GCU) current sensor voltage is at least 2.611 volts (39 amperes) and not more than 2.389 volts (-39 amperes) continues for 0.4 seconds.
- When the IGBT status of the power drive unit (GCU) changes from off to on, when the power drive unit (GCU) current sensor voltage is at least 2.611 volts (39 amperes) and not more than 2.389 volts (-39 amperes).