DIAGNOSTIC FUNCTION
If a predetermined current does not flow into the line pressure solenoid valve (short to ground), the TCM will determine the system is defective.
DESCRIPTIONS OF MONITOR METHODS
The solenoid valve drive circuit remains short to ground for 0.2 seconds.
MONITOR EXECUTION
- Voltage of battery: 10 volts or more.
MONITOR EXECUTION CONDITIONS (OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
- P0966, P0967: Malfunction of secondary pressure solenoid valve
Sensor (The sensor below is determined to be normal)
LOGIC FLOW CHARTS (Monitor Sequence)
DTC SET CONDITIONS
Check Conditions
- Voltage of battery: 10 volts or more.
Judgment Criteria
- Line pressure solenoid valve actual current: 1.78 A or more (0.2 seconds).
OBD-II DRIVE CYCLE PATTERN
Ignition switch: ON (start the engine and keep it for 5 seconds or more)
PROBABLE CAUSES
- Malfunction of the valve body assembly (Faulty line pressure solenoid valve)
- Damaged wiring harness and connectors
- Malfunction of TCM