[Previous][Next]
Inspection Procedure 16: ACC power auto cut function does not work normally.
 
 
cautionBefore replacing the ECU, ensure that the power supply circuit, the ground circuit and the communication circuit are normal.
 
 
COMMENTS ON TROUBLE SYMPTOM
The KOS&OSS-ECU will evaluate the signals from the power supply mode "ACC" and the driver's door switch to determine whether the "ACC" power supply is shut down or not. If this function does not work normally, the input signal or the KOS&OSS-ECU may be defective. Also, "ACC power auto cut time" may be set to "Disable" through customization.
 
 
PROBABLE CAUSES
  • Malfunction of KOS&OSS-ECU
  • Malfunction of the driver's door switch
  • External noise interruption in input signal
  • Malfunction of selector lever assembly (ON seizure of P range detection switch)
 
 
DIAGNOSIS
STEP 1. Check of customization function
Use the ETACS-ECU customization function to check whether "ACC power auto cut time" is set to "30 min" or "60 min."
Is the check result normal?
Go to Step 2.
Using the ETACS-ECU customization function, set ACC power auto cut time" to "30 min" or "60 min" (Refer to ).
 
STEP 2. Using scan tool (M.U.T.-IIISE), check the DTC.
Check if any DTC is set in the KOS&OSS-ECU.
Is the DTC set?
Refer to diagnostic trouble code chart .
Go to Step 3.
 
STEP 3. Check of short to ground in PDSW line between selector lever assembly connector and KOS&OSS-ECU connector
noteBecause the conformity cannot be determined even when the digital tester is used to measure the voltage of PDSW line between the selector lever assembly connector and KOS&OSS-ECU connector, be sure to use the oscilloscope (Outputs the sawtooth waveform of 0 to 5 volts with intervals of 10 ms.).
Is the check result normal?
Go to Step 4.
Repair the connector(s) or wiring harness.
 
STEP 4. Check of selector lever assembly (P range detection switch)
Disconnect the selector lever assembly connector, and check the continuity at the equipment side.
 
Operation stateTerminal No.Normal conditions
Selector lever: P position3 - 6No continuity
Selector lever: Other than P positionContinuity exists (2Ω or less)
Operation stateTerminal No.Normal conditions
Selector lever: P position3 - 6No continuity
Selector lever: Other than P positionContinuity exists (2Ω or less)
Is the check result normal?
Go to Step 5.
Replace the selector lever assembly (Refer to GROUP 23A - Transaxle Control ).
 
STEP 5. Using scan tool (M.U.T.-IIISE), check the data list
Check the KOS&OSS-ECU data list.
  • Operate the selector lever.
 
Item No.Check itemOperation stateDisplay
7P position detect switchSelector lever: P positionP
Selector lever: Other than P positionExcept P
Item No.Check itemOperation stateDisplay
7P position detect switchSelector lever: P positionP
Selector lever: Other than P positionExcept P
OK: Operation state and data list display agree with each other.
Is the check result normal?
Go to Step 6.
Replace the KOS&OSS-ECU and register the ID codes (Refer to ).
 
STEP 6. Using scan tool (M.U.T.-IIISE), check the other system data list
Check the ETACS-ECU data list.
  • Check the signal from the driver's door.
Open the driver's door.
 
Item No.Check itemNormal conditions
81Driver's door ajar switchON
Item No.Check itemNormal conditions
81Driver's door ajar switchON
OK: Normal conditions are displayed.
Is the check result normal?
Go to Step 7.
Perform input signal check for the ETACS (Refer to GROUP 54A - ETACS - Input Signal Check ).
 
STEP 7. Voltage measurement at KOS&OSS-ECU connector
Check the voltage measurement at KOS&OSS-ECU connector (Refer to ).
Terminals to be checked
  • STP1
  • SW1
  • PDSW
  • SW2
Is the check result normal?
Go to Step 8.
Replace the KOS&OSS-ECU and register the ID codes (Refer to ).
 
STEP 8. Using scan tool (M.U.T.-IIISE), check the data list
Use the KOS&OSS-ECU service data to check the signals related to the ACC power auto cut function.
  • Turn the power supply mode to "ACC."
 
Item No.Check itemNormal conditions
8OSS power supply statusIG ACC
Item No.Check itemNormal conditions
8OSS power supply statusIG ACC
OK: Normal conditions are displayed.
Is the check result normal?
Go to Step 9.
Replace the KOS&OSS-ECU and register the ID codes (Refer to ).
 
STEP 9. Check of the troubles
Check whether the ACC power auto cut function works normally.
Is the check result normal?
Intermittent malfunction is suspected (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).
Replace the KOS&OSS-ECU and register the ID codes (Refer to ).