MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
- Rear motor current sensor (Upper/Lower limit malfunction) <DTC No. P0BF2-00, P0BF6-00, P0BFA-00>
DTC SET CONDITIONS
Check Condition A <DTC No.P0BF2-00, P0BF6-00, P0BFA-00>
- REMCU power supply voltage is 8.0 volts or more.
- The IGBT status is OFF (Shutdown).
- Rear drive motor revolution speed is 3,500 rpm or less.
Check Condition B <DTC No.P0BF2-00, P0BF6-00, P0BFA-00>
- REMCU power supply voltage is 8.0 volts or more.
- The IGBT status becomes ON from OFF.
- Rear drive motor revolution speed is 3,500 rpm or less.
Check Condition <DTC No.P0BF3-00, P0BF4-00, P0BF7-00, P0BF8-00, P0BFB-00, P0BFC-00>
- REMCU power supply voltage is 8.0 volts or more.
Judgment Criterion <DTC No.P0BF2-00, P0BF6-00, P0BFA-00>
- The voltage is 2.611 volts or more, or 2.389 volts or less for 0.18 second or more.
Judgment Criterion <DTC No.P0BF3-00, P0BF7-00, P0BFB-00>
- The voltage is 4.7 volts or more for 0.18 second or more.
Judgment Criterion DTC No. P0BF4-00, P0BF8-00, P0BFC-00>
- The voltage is 0.3 volts or less for 0.18 second or more.