DTC No. P3016-16 FMCU gate driver power supply malfunction DTC No. P30A1-16 GCU gate driver power supply malfunction DTC No. P3018-16 VCU gate driver power supply malfunction
MONITOR EXECUTION
Continuous
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Not applicable
Sensor (The sensor below is determined to be normal)
Not applicable
DTC SET CONDITIONS
Logic Flow Chart
Check Condition <DTC No.P3016-16>
Power drive unit (FEMCU) power supply voltage is 8.0 volts or more.
Check Condition <DTC No.P30A1-16>
Power drive unit (GCU) power supply voltage is 8.0 volts or more.
Check Condition <DTC No.P3018-16>
Power drive unit (VCU) power supply voltage is 8.0 volts or more.
Judgment Criterion
Detected IGBT driver power supply voltage malfunction switch is ON (When the IGBT driver power supply voltage is less than 10 volts, the voltage malfuncition switch turns on) for 0.12 seconds.
The trouble can be an intermittent malfunction (Refer to General Information - How to Use Troubleshooting/Inspection Service Points, How to Cope with Intermittent Malfunctions HOW TO COPE WITH INTERMITTENT MALFUNCTIONS).
3.Test the OBD-II drive cycle.
(1) Carry out a test drive with the drive cycle pattern. Refer to OBD-II Drive Cycle OBD-II DRIVE CYCLE.