MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)
DTC SET CONDITIONS
Check Condition
- Power drive unit (FEMCU) power supply voltage is 8.0 volts or more.
Judgment Criterion <DTC No. P0BE7-00>
- The FEMCU U-phase current sensor voltage is 0.5 volt or less for 0.14 second or more.
Judgment Criterion <DTC No. P0BE8-00>
- The FEMCU U-phase current sensor voltage is 4.5 volts or more for 0.14 second or more.
Judgment Criterion <DTC No. P0BEB-00>
- The FEMCU V-phase current sensor voltage is 0.5 volt or less for 0.14 second or more.
Judgment Criterion <DTC No. P0BEC-00>
- The FEMCU V-phase current sensor voltage is 4.5 volts or more for 0.14 second or more.
Judgment Criterion <DTC No. P0BEF-00>
- The FEMCU W-phase current sensor voltage is 0.5 volt or less for 0.14 second or more.
Judgment Criterion <DTC No. P0BF0-00>
- The FEMCU W-phase current sensor voltage is 4.5 volts or more for 0.14 second or more.