[Previous][Next]
Diagnosis Procedure
1.CHECK BATTERY
Check battery. Refer to Work Flow.
Is the inspection result normal?
.
Repair or replace the malfunctioning parts.
 
2.CHECK CHARGING SYSTEM
Check charging system condition. Refer to Work Flow (With EXP-800 NI or GR8-1200 NI) or Work Flow (Without EXP-800 NI or GR8-1200 NI).
Is the inspection result normal?
.
Repair or replace the malfunctioning parts.
 
3.CHECK COMBINATION METER POWER SUPPLY CIRCUIT
Check combination meter power supply circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
Replace combination meter. Refer to Removal and Installation.
Repair or replace the malfunctioning parts.