[Previous][Next]
Diagnosis Procedure
1.CHECK Power liftgate REQUEST SWITCH INPUT SIGNAL
  1. Ignition switch OFF.
  2. Disconnect power liftgate opener switch connector.
  3. Check voltage between power liftgate opener switch harness connector and ground.
    (+)(–)Voltage
    Power liftgate opener switch
    ConnectorTerminal
    D5074Ground12 V
Is the inspection result normal?
.
.
 
2.CHECK Power liftgate REQUEST SWITCH CIRCUIT
  1. Disconnect Keyless operation key unit connector.
  2. Check continuity between power liftgate opener switch harness connector and Keyless operation key unit harness connector.
    Power liftgate opener switchKeyless operation key unitContinuity
    ConnectorTerminalConnectorTerminal
    D5074M1845Existed
  3. Check continuity between power liftgate opener switch harness connector and ground.
    Power liftgate opener switchContinuity
    ConnectorTerminal
    D5074GroundNot existed
Is the inspection result normal?
Replace Keyless operation key unit. Refer to Removal and Installation.
Repair or replace harness.
 
3.CHECK Power liftgate REQUEST SWITCH GROUND CIRCUIT
Check continuity between power liftgate opener switch harness connector and ground.
Power liftgate opener switchContinuity
ConnectorTerminal
D5073GroundExisted
Is the inspection result normal?
.
Repair or replace harness.
 
4.CHECK Power liftgate REQUEST SWITCH
Refer to Component Inspection.
Is the inspection result normal?
.
Replace power liftgate opener switch. Refer to Removal and Installation.
 
5.CHECK INTERMITTENT INCIDENT
Refer to Intermittent IncidentIntermittent Incident.
: INSPECTION END