1.CHECK Power liftgate REQUEST SWITCH INPUT SIGNAL
2.CHECK Power liftgate REQUEST SWITCH CIRCUIT
- Disconnect Keyless operation key unit connector.
- Check continuity between power liftgate opener switch harness connector and Keyless operation key unit harness connector.
Power liftgate opener switch | Keyless operation key unit | Continuity |
Connector | Terminal | Connector | Terminal |
D507 | 4 | M184 | 5 | Existed |
- Check continuity between power liftgate opener switch harness connector and ground.
Power liftgate opener switch | — | Continuity |
Connector | Terminal |
D507 | 4 | Ground | Not existed |
Is the inspection result normal?
Repair or replace harness.
3.CHECK Power liftgate REQUEST SWITCH GROUND CIRCUIT
4.CHECK Power liftgate REQUEST SWITCH
5.CHECK INTERMITTENT INCIDENT