1.CHECK DOOR REQUEST SWITCH INPUT SIGNAL
2.CHECK DOOR REQUEST SWITCH CIRCUIT
- Disconnect Keyless operation key unit connector.
- Check continuity between front door request switch RH harness connector and Keyless operation key unit harness connector.
Front door request switch RH | Keyless operation key unit | Continuity |
Connector | Terminal | Connector | Terminal |
D116 | 1 | M184 | 11 | Existed |
- Check continuity between front door request switch RH harness connector and ground.
Front door request switch RH | — | Continuity |
Connector | Terminal |
D116 | 1 | Ground | Not existed |
Is the inspection result normal?
Repair or replace harness.
3.CHECK DOOR REQUEST SWITCH GROUND CIRCUIT
4.CHECK DOOR REQUEST SWITCH
5.CHECK INTERMITTENT INCIDENT