STEP 1. Check of open circuit, short to ground, and damage in FBAK line between A/C controller assembly (A/C-ECU) connector C-216 and blower motor connector C-249.
STEP 2. Check of open circuit, short to ground, and damage in BLOD line between A/C controller assembly (A/C-ECU) connector C-216 and blower motor connector C-249.
STEP 3. Voltage measurement at blower motor connector C-249.
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between the blower motor connector C-249 terminal 1 and body ground.OK: System voltage
Is the check result normal?
Go to Step 4. Refer to inspection procedure "Blower motor power supply system"
STEP 4. Check of open circuit, and damage in E line between blower motor connector C-249 and body ground.
STEP 5. M.U.T.-III DTC Check that DTC No.B1191, B1192 or B1193 is also set.
STEP 6. Recheck the trouble symptom.
STEP 7. Recheck the trouble symptom.
Is the check result normal?