STEP 3. Check the side impact sensor (Front: RH) power supply circuit. Measure the voltage at the side impact sensor (front RH) connector D-01.
(1) Disconnect the negative battery terminal.
(2) Disconnect side impact sensor (Front: RH) connector D-01, and measure at the wiring harness side.
(3) Connect the negative battery terminal.
(4) Turn the ignition switch to the "ON" position.
(5) caution | Do not insert a test probe into the terminal from its front side directly, as the connector contact pressure may be weakened. |
Measure the voltage between D-01 harness side connector terminal 1and ground.
Voltage should measure 9 volts or more
Is the measured voltage within the specified range?
Replace the side impact sensor (Front: RH). (Refer to ). Then go to Step 5. Go to Step 4.