Line pressure solenoid valve | 1 | 5 | Continuity exists (2 Ω or less) |
1 | Other than above | No continuity |
Primary pressure solenoid valve | 2 | 12 | Continuity exists (2 Ω or less) |
2 | Other than above | No continuity |
Secondary pressure solenoid valve | 3 | 4 | Continuity exists (2 Ω or less) |
3 | Other than above | No continuity |
Select solenoid valve | 4 | 2 | Continuity exists (2 Ω or less) |
4 | Other than above | No continuity |
Lock-up solenoid valve | 5 | 3 | Continuity exists (2 Ω or less) |
5 | Other than above | No continuity |
Primary pressure sensor | 13 | 11 | Continuity exists (2 Ω or less) |
13 | Other than above | No continuity |
Secondary pressure sensor | 14 | 9 | Continuity exists (2 Ω or less) |
14 | Other than above | No continuity |
Sensor earth | 18 | 8 | Continuity exists (2 Ω or less) |
18 | Other than above | No continuity |
Sensor power supply | 22 | 10 | Continuity exists (2 Ω or less) |
22 | Other than above | No continuity |