1. Disconnect the connector "B" of the main drive lithium-ion battery.
danger
When pulling service plugs, wear the specified protective equipment (Refer to ).
2. Measure the resistance between the main drive lithium-ion battery connector "B" terminal No. 1 and No. 2.
Service plug status
Normal condition
Inserted service plug
Continuity (2 Ω or less)
Disconnected service plug
No continuity
3. If the resistance deviates from the standard value, the circuit and the terminal resistance can have an abnormality inside the main drive lithium-ion battery.