STEP 3. Using scan tool (M.U.T.-IIISE), check the data list.
(1) Turn off the power supply mode of the electric motor switch.
(2) Operate the electric motor switch twice without depressing on the brake pedal and turn on the power supply mode.
(3) Wait at least 5 seconds.
(4) Check that the following data list display contents are normal (Refer to ).OK: 500 r/min
Is the check result normal?
Go to Step 5. Go to Step 4.