TECHNICAL DESCRIPTION (COMMENT)
A wireless LAN device cannot communicate with the vehicle (EV remote-ECU) only (the device can communicate with other devices), the environment where the device is used is poor, the external antenna or the EV remote-ECU is defective.
note | - Use the inquiry blank to confirm the environment where the wireless LAN device is used. Then attempt to communicate with the EV remote-ECU. If you find any faults, follow this procedure.
- If any of the conditions below is satisfied, the MITSUBISHI remote control system will disable the wireless LAN communication to avoid the 12V starter battery discharge due to static current.
- Control at normal temperature: Will be disabled when the power supply mode of the electric motor switch remains off and the DC/DC converter remains off for at least 36 hours. If the power supply mode of the electric motor switch remains on and the DC/DC converter remains on for ten minutes, the wireless LAN communication will be enabled again. (If the DC/DC converter does not remain on for ten minutes even if the power supply mode of the electric motor switch is on, the wireless LAN communication will be disabled again)
- Control at low temperature: Will be disabled when the power supply mode of the electric motor switch remains at any status other than "ready" for at least 36 hours at an ambient temperature of -15°C (5°F) or less. If the power supply mode of the electric motor switch remains at ready status for ten minutes, the wireless LAN communication will be enabled again (If the DC/DC converter does not remain on for ten minutes even if the power supply mode of the electric motor switch is on, the wireless LAN communication will be disabled again).
|