STEP 1. Using scan tool (M.U.T.-IIISE), check data list
(1) Disconnect the negative battery terminal and wait for approximately 30 seconds.
(2) Check the signals related to the power liftgate operation.- Liftgate sensor (left): OFF → ON
- Liftgate sensor (right): OFF → ON
| Item No. | Item name | Normal conditions | 9 | Touch sensor (Left) | OFF → ON | 10 | Touch sensor (Right) | OFF → ON |
|
OK: Normal conditions are displayed for all the items.
Is the check result normal?
: Go to Step 7. : Go to Step 2. : Go to Step 3. : Go to Step 5.
STEP 2. Check of open circuit in TSG line between power liftgate control unit connector and liftgate sensor (LH) and (RH) connector.
STEP 3. Liftgate sensor (LH) check.
STEP 4. Check of short to power supply, short to ground, and open circuit in TSL line between power liftgate control unit connector and liftgate sensor (LH) connector.
STEP 5. Liftgate sensor (RH) check.
STEP 6. Check of short to power supply, short to ground, and open circuit in TSR line between power liftgate control unit connector and liftgate sensor (RH) connector.
STEP 7. Check of the troubles