[Previous][Next]
INSPECTION
 
 
LIFTGATE LATCH CHECK
 
 
LATCH MOTOR OPERATION CHECK
 
Battery connecting terminal numberGear operation
1 (negative battery terminal) - 9 (positive battery terminal)Engaged → Disengaged
1 (positive battery terminal) - 9 (negative battery terminal)Disengaged → Engaged
 
 
 
HALF LATCH SWITCH CHECK
 
Claw positionTerminal numberNormal value
ON2 - 3Continuity exists (2 Ω or less).
OFF2 - 3No continuity
 
 
 
FULL LATCH SWITCH CHECK
 
Claw positionTerminal numberNormal value
ON2 - 4Continuity exists (2 Ω or less).
OFF2 - 4No continuity
 
 
 
DOOR-AJAR SWITCH CHECK
 
Claw positionTerminal numberNormal value
ON5 - 10Continuity exists (2 Ω or less).
OFF5 - 10No continuity
 
 
 
NEUTRAL SWITCH CHECK
cautionAfter checking the neutral switch, operate the liftgate latch as follows to install it. This avoids damage to the liftgate latch switch.
  1. Connect the positive battery terminal to the liftgate latch terminal No.1, and the negative battery terminal to the liftgate latch terminal No.9 for approximately one second.
  2. Connect the positive battery terminal to the liftgate latch terminal No.9, and the negative battery terminal to the liftgate latch terminal No.1 for approximately one second.
 
Lever positionTerminal numberNormal value
ON7 - 8Continuity exists (2 Ω or less).
OFF7 - 8No continuity
 
 
 
 
LIFTGATE SENSOR CHECK
When the load is applied to the pressure detection sensor towards the direction shown in the figure, and when the sensor is pushed approximately 2.2 mm, the liftgate sensor turns ON.
 
Sensor positionTerminal numberNormal value
ON1 - 2 100 Ω or less
OFF1 - 2 Approximately 1kΩ
 
 
 
POWER LIFTGATE CLOSE SWITCH INSPECTION
 
Switch positionTerminal numberNormal value
ON (Press)1 - 2 Continuity exists (2 Ω or less)
OFF1 - 2 No continuity
 
 
 
POWER LIFTGATE MAIN SWITCH CHECK
 
Switch positionTerminal numberNormal value
ON (Press)1 - 2 Continuity exists (2 Ω or less)
OFF1 - 2 No continuity
 
 
 
POWER LIFTGATE SWITCH CHECK
 
Switch positionTerminal numberNormal value
ON (Press)10 - 13Continuity exists (2 Ω or less)
OFF10 - 13No continuity
 
 
 
POWER LIFTGATE TONE ALARM INSPECTION
Check that the power liftgate tone alarm sounds once when the terminals are connected to the battery as shown.
 
 
 
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK
 
Switch positionTerminal numberNormal value
Push (open)1 - 2 Continuity exists (2 Ω or less)
Release1 - 2 No continuity
 
 
 
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE LOCK SWITCH) CHECK
 
Switch positionTerminal numberNormal value
Push (lock)2 - 3 Continuity exists (2 Ω or less)
Release2 - 3 No continuity