After checking the neutral switch, operate the liftgate latch as follows to install it. This avoids damage to the liftgate latch switch.
Connect the positive battery terminal to the liftgate latch terminal No.1, and the negative battery terminal to the liftgate latch terminal No.9 for approximately one second.
Connect the positive battery terminal to the liftgate latch terminal No.9, and the negative battery terminal to the liftgate latch terminal No.1 for approximately one second.
Lever position
Terminal number
Normal value
ON
7 - 8
Continuity exists (2 Ω or less).
OFF
7 - 8
No continuity
LIFTGATE SENSOR CHECK
When the load is applied to the pressure detection sensor towards the direction shown in the figure, and when the sensor is pushed approximately 2.2 mm, the liftgate sensor turns ON.
Sensor position
Terminal number
Normal value
ON
1 - 2
100 Ω or less
OFF
1 - 2
Approximately 1kΩ
POWER LIFTGATE CLOSE SWITCH INSPECTION
Switch position
Terminal number
Normal value
ON (Press)
1 - 2
Continuity exists (2 Ω or less)
OFF
1 - 2
No continuity
POWER LIFTGATE MAIN SWITCH CHECK
Switch position
Terminal number
Normal value
ON (Press)
1 - 2
Continuity exists (2 Ω or less)
OFF
1 - 2
No continuity
POWER LIFTGATE SWITCH CHECK
Switch position
Terminal number
Normal value
ON (Press)
10 - 13
Continuity exists (2 Ω or less)
OFF
10 - 13
No continuity
POWER LIFTGATE TONE ALARM INSPECTION
Check that the power liftgate tone alarm sounds once when the terminals are connected to the battery as shown.
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK