STEP 1. Check the MFI relay.
STEP 2. Measure the power supply voltage at MFI relay harness side connector.
(1) Disconnect the MFI relay connector and measure at the harness side.
(2) Measure the voltage between terminals power supply line and ground.- Voltage should be 12V starter battery positive voltage.
Is 12V starter battery positive voltage (approximately 12 volts) present?
Go to Step 3. Repair or replace the connector(s), or check and repair the harness of open circuit and short circuit to ground in power supply line between fusible link and MFI relay connector. Then confirm that the malfunction symptom is eliminated.
STEP 3. Measure the OSS-ECU (IG1) signal voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Turn on the power supply mode of the electric motor switch.
(3) Measure the voltage between terminal IGN and ground.- Voltage should be 12V starter battery positive voltage.
(4) Turn off the power supply mode of the electric motor switch.
Is 12V starter battery positive voltage (approximately 12 volts) present?
Go to Step 7. Go to Step 4.
STEP 4. Measure the OSS-ECU (IG1) signal voltage at ETACS-ECU harness side connector.
(1) Disconnect the ETACS-ECU connector and measure at the harness side.
(2) Turn on the power supply mode of the electric motor switch.
(3) Measure the voltage between terminal IGS and ground.- Voltage should be 12V starter battery positive voltage
(4) Turn off the power supply mode of the electric motor switch.
Is 12V starter battery positive voltage (approximately 12 volts) present?
Go to Step 6. Go to Step 5.
STEP 5. Check of short to ground and open circuit in IG1 to IGS line between OSS-ECU connector and ETACS-ECU connector.
STEP 6. Check the continuity at ETACS-ECU side connectors.
(1) Disconnect the ETACS-ECU connector and measure at the ETACS-ECU side.
(2) Check for the continuity between terminal IGS and EIG1.note | Connect the (+) side of circuit tester to terminal EIG1. |
Does continuity exist?
Repair or replace the connector(s), or check and repair the harness of short to ground and open circuit in EIG1 to IGN line between ETACS-ECU connector and ECM connector. Then confirm that the malfunction symptom is eliminated. Replace the ETACS-ECU. Then confirm that the malfunction symptom is eliminated.
STEP 7. Check the continuity at ETACS-ECU side connectors.
(1) Disconnect the ETACS-ECU connector and measure at the ETACS-ECU side.
(2) Check for the continuity between terminal IGS and EIG1.note | Connect the (+) side of circuit tester to terminal EIG1. |
Does continuity exist?
Go to Step 8. Replace the ETACS-ECU. Then confirm that the malfunction symptom is eliminated.
STEP 8. Check of harness damage in IG1 to IGS line between OSS-ECU connector and ETACS-ECU connector.
STEP 9. Check of harness damage in EIG1 to IGN line between ETACS-ECU connector and ECM connector.
STEP 10. Measure the backup power supply voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Measure the voltage between terminal BACK and ground.- Voltage should be 12V starter battery positive voltage.
Is 12V starter battery positive voltage (approximately 12 volts) present?
Go to Step 11. Repair or replace the connector(s), or check and repair the harness of open circuit and short circuit to ground in BACK line between fusible link and ECM connector. Then confirm that the malfunction symptom is eliminated.
STEP 11. Check the continuity at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Check for the continuity between terminals GNDB, GNDE and ground.- Continuity (2 ohms or less).
Does continuity exist?
Go to Step 12. Repair or replace the connector(s), or check and repair the harness of open circuit and damage in GNDB, GNDE line between ECM connector and ground. Then confirm that the malfunction symptom is eliminated.
STEP 12. Measure the power supply voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Measure the voltage between terminal C/R and ground.- Voltage should be 12V starter battery positive voltage.
Is 12V starter battery positive voltage (approximately 12 volts) present?
Go to Step 13. Repair or replace the connector(s), or check and repair the harness of open circuit and short circuit to ground in C/R line between MFI relay connector and ECM connector. Then confirm that the malfunction symptom is eliminated.
STEP 13. Measure the power supply voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Short-circuit the terminal C/R of the ECM harness connector to the ground.
(3) Measure the voltage between terminal BAT1 and ground.- Voltage should be 12V starter battery positive voltage.
Is 12V starter battery positive voltage (approximately 12 volts) present?
Go to Step 16. Go to Step 14.
STEP 14. Check of short to ground and open circuit in BAT1 line between MFI relay connector and ECM connector.
STEP 15. Check of harness damage in power supply line between fusible link and MFI relay connector.
Is the harness wire in good condition?
Repair or replace the connector(s), or check and repair the harness of damage in C/R line between MFI relay connector and ECM connector. Then confirm that the malfunction symptom is eliminated. Repair the connector(s) or wiring harness. Then confirm that the malfunction symptom is eliminated.
STEP 16. Check of harness damage in BAT1 line between MFI relay connector and ECM connector.