STEP 1. Check the MFI relay.
STEP 2. Measure the power supply voltage at MFI relay harness side connector.
(1) Disconnect the MFI relay connector and measure at the harness side.
(2) Measure the voltage between terminals power supply line and ground.- Voltage should be battery positive voltage.
Is battery positive voltage (approximately 12 volts) present?
Go to Step 3. Repair or replace the connector(s), or check and repair the harness of open circuit and short circuit to ground in power supply line between fusible link and MFI relay connector. Then confirm that the malfunction symptom is eliminated.
STEP 3. Measure the ignition switch-IG signal voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal IGN line and ground.- Voltage should be battery positive voltage.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Is battery positive voltage (approximately 12 volts) present?
Go to Step 8. Go to Step 4.
STEP 4. Measure the ignition switch-IG signal voltage at ETACS-ECU harness side connector.
(1) Disconnect the ETACS-ECU connector and measure at the harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal IG1 and ground.- Voltage should be battery positive voltage
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Is battery positive voltage (approximately 12 volts) present?
Go to Step 7. : Go to Step 5. : Go to Step 6.
STEP 5. Check the ignition switch
STEP 6. Check of short to ground and open circuit between OSS-ECU connector and ETACS-ECU connector.
STEP 7. Check the continuity at ETACS-ECU side connectors.
(1) Disconnect the ETACS-ECU connector and measure at the ETACS-ECU side.
(2) Check for the continuity between terminal IG1 and IGN.note | Connect the (+) side of circuit tester to terminal IGN. |
Does continuity exist?
Repair or replace the connector(s), or check and repair the harness of short to ground and open circuit in IGN line between ETACS-ECU connector and ECM connector. Then confirm that the malfunction symptom is eliminated. Replace the ETACS-ECU. Then confirm that the malfunction symptom is eliminated.
STEP 8. Check the continuity at ETACS-ECU side connectors.
(1) Disconnect the ETACS-ECU connector and measure at the ETACS-ECU side.
(2) Check for the continuity between terminal IG1 and IGN.note | Connect the (+) side of circuit tester to terminal IGN. |
Does continuity exist?
: Go to Step 9. : Go to Step 10. Replace the ETACS-ECU. Then confirm that the malfunction symptom is eliminated.
STEP 9. Check of harness damage in IG1 line between ignition switch connector and ETACS-ECU connector.
STEP 10. Check for harness damage in IG1 line between OSS-ECU connector and ETACS-ECU connector.
STEP 11. Check for harness damage in IGN line between ETACS-ECU connector and ECM connector.
STEP 12. Measure the backup power supply voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Measure the voltage between terminal BACK and ground.- Voltage should be battery positive voltage.
Is battery positive voltage (approximately 12 volts) present?
Go to Step 13. Repair or replace the connector(s), or check and repair the harness of open circuit and short circuit to ground in BACK line between fusible link and ECM connector. Then confirm that the malfunction symptom is eliminated.
STEP 13. Check the continuity at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Check for the continuity between terminals GNDB, GNDE and ground.- Continuity (2 ohms or less).
Does continuity exist?
Go to Step 14. Repair or replace the connector(s), or check and repair the harness of open circuit and damage in GNDB, GNDE line between ECM connector and ground. Then confirm that the malfunction symptom is eliminated.
STEP 14. Measure the power supply voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Measure the voltage between terminal C/R and ground.- Voltage should be battery positive voltage.
Is battery positive voltage (approximately 12 volts) present?
Go to Step 15. Repair or replace the connector(s), or check and repair the harness of open circuit and short circuit to ground in C/R line between MFI relay connector and ECM connector. Then confirm that the malfunction symptom is eliminated.
STEP 15. Measure the power supply voltage at ECM harness side connector.
(1) Disconnect the ECM connector and measure at the harness side.
(2) Short-circuit the terminal C/R of the ECM harness connector to the ground.
(3) Measure the voltage between terminal BAT1 and ground.- Voltage should be battery positive voltage.
Is battery positive voltage (approximately 12 volts) present?
Go to Step 18. Go to Step 16.
STEP 16. Check of short to ground and open circuit in BAT1 line between MFI relay connector and ECM connector.
STEP 17. Check of harness damage in power supply line between fusible link and MFI relay connector.
Is the harness wire in good condition?
Repair or replace the connector(s), or check and repair the harness of damage in C/R line between MFI relay connector and ECM connector. Then confirm that the malfunction symptom is eliminated. Repair the connector(s) or wiring harness. Then confirm that the malfunction symptom is eliminated.
STEP 18. Check of harness damage in BAT1 line between MFI relay connector and ECM connector.