DTC P2251: Linear Air-Fuel Ratio Sensor Negative Current Control Circuit/Open (bank 1)
CIRCUIT OPERATION
The right bank linear air-fuel ratio sensor and the ECM are connected by the following three lines to detect the air-fuel ratio.
- The line between the right bank linear air-fuel ratio sensor and the ECM terminal LPFR detects the air-fuel ratio.
- The auxiliary line between the right bank linear air-fuel ratio sensor and the ECM terminal LSFR detects the air-fuel ratio.
- The line between the right bank linear air-fuel ratio sensor and the ECM terminal LEFR is connected to ground.
TECHNICAL DESCRIPTION
- The ECM effects air/fuel ratio feedback control in accordance with the signals from the right bank linear air-fuel ratio sensor.
- If the right bank linear air-fuel ratio sensor has deteriorated, corrections will be made by the right bank heated oxygen sensor (rear).
DESCRIPTIONS OF MONITOR METHODS
- The right bank linear air-fuel ratio sensor heater or the exhaust gas heats the right bank linear air-fuel ratio sensor to sufficiently activate the right bank linear air-fuel ratio sensor, resulting in the small resistance. However, the DTC is set as an open circuit if the large resistance continues.
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
- Linear air-fuel ratio sensor heater monitor
- Misfire monitor
- Fuel system monitor
Sensor (The sensor below is determined to be normal)
- Mass airflow sensor
- Engine coolant temperature sensor
- Intake air temperature sensor
- Barometric pressure sensor
- Throttle position sensor
- Accelerator pedal position sensor
Check Conditions
- Battery positive voltage is between 10 and 16.5 volts.
- More than 245 seconds have passed since the engine starting sequence was completed.
Judgment Criteria
- The sensor impedance is be higher than 450 ohms for 2 seconds.
- The reference circuit voltage is be lower than 5.3 volts for 2 seconds.
FAIL-SAFE AND BACKUP FUNCTION
- Does not control air-fuel ratio closed loop.
- Control Right bank linear air-fuel ratio sensor heater off
OBD-II DRIVE CYCLE PATTERN
- Refer to Diagnosis Function - OBD-II Drive Cycle - Pattern 21 .
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)
- Right bank linear air-fuel ratio sensor failed.
- Open right bank linear air-fuel ratio sensor circuit, or connector damage.
- ECM failed.