DTC P0102: Volume Airflow Circuit Low Input


CIRCUIT OPERATION
• The volume airflow sensor power is supplied from the MFI relay (terminal No. 1), and the ground is provided on the PCM (terminal No. 57).
• 5-volt power is applied to the volume airflow sensor output terminal (terminal No. 3) from the PCM (terminal No. 65). The volume airflow sensor generates a pulse signal when the output terminal and ground are opened/closed (opened/short).
TECHNICAL DESCRIPTION
• While the engine is running, the volume airflow sensor outputs a pulse signal which corresponds to the volume of air flow.
• The PCM checks whether the frequency of this signal output by the volume airflow sensor while the engine is running is at or above the set value.
DESCRIPTIONS OF MONITOR METHODS
Volume airflow sensor output frequency is out of specified range.
MONITOR EXECUTION
Continuous
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)

Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
• Not applicable

Sensor (The sensor below is determined to be normal)
• Not applicable
DTC SET CONDITIONS Logic Flow Chart


Check Conditions
Engine speed is higher than 500 r/min.

Judgement Criteria
• Volume airflow sensor output frequency has continued to be 3.3 Hz or lower for 2 seconds.
OBD-II DRIVE CYCLE PATTERN
Refer to Diagnostic Function - OBD-II Drive Cycle - Procedure 6 - Other Monitor .
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are: )
• Volume airflow sensor failed.
• Open or shorted volume airflow sensor circuit, harness damage or connector damage.
• PCM failed.