STEP 1. Confirmation of the defective door lock actuator or liftgate lock actuator.
STEP 2. Front door lock actuator (LH) check
STEP 3. Check of short to power supply, short to ground, and open circuit in DUN, DLK1&DLK2&DLK4 line between ETACS-ECU connector and front door lock actuator (LH) connector.
STEP 4. Front door lock actuator (RH) check
STEP 5. Check of short to power supply, short to ground, and open circuit in DUL2, DLK1&DLK2&DLK4 line between ETACS-ECU connector and front door lock actuator (RH) connector.
STEP 6. Rear door lock actuator (LH) check
STEP 7. Check of short to power supply, short to ground, and open circuit in DUL3, DLK3 line between ETACS-ECU connector and rear door lock actuator (LH) connector.
STEP 8. Rear door lock actuator (RH) check
STEP 9. Check of short to power supply, short to ground, and open circuit in DUL3, DLK1&DLK2&DLK4 line between ETACS-ECU connector and rear door lock actuator (RH) connector.
STEP 10. liftgate lock actuator check.
STEP 11. Resistance measurement at liftgate lock actuator connector (ground line terminal).
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the liftgate lock actuator connector (ground line terminal) and body ground.OK: The resistance should be 2 ohms or less.
Is the check result normal?
Go to Step 13. Go to Step 12.
STEP 12. Check of open circuit in ground line between liftgate lock actuator connector and body ground.
STEP 13. Check of open circuit in GLK line between ETACS-ECU connector and liftgate lock actuator connector.