INSPECTION
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK <VEHICLES WITH KEYLESS OPERATION SYSTEM>
Refer to GROUP 42B - Lock/unlock Switch Inspection.
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK <VEHICLES WITHOUT KEYLESS OPERATION SYSTEM>
Switch position
Terminal number
Normal value
Push (open)
1 - 2
The resistance should be 2 ohms or less.
Release
1 - 2
No continuity
LIFTGATE LOCK ACTUATOR CHECK
Lever position
Battery connection
Lever operation
At the "SET" position
Connect terminal 2 to negative battery terminal.
Connect terminal 3 to positive battery terminal.
Lever moves from "SET" to "OPEN" position.
LIFTGATE LATCH SWITCH CHECK
Claw position
Terminal number
Normal value
Unlatch (ON)/ Half-latch (ON)
1 - 2
The resistance should be 2 ohms or less.
Full-latch (OFF)
1 - 2
No continuity