[Previous][Next]
INSPECTION
 
 
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK <VEHICLES WITH KEYLESS OPERATION SYSTEM>
Refer to GROUP 42B - Lock/unlock Switch Inspection.
 
 
 
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK <VEHICLES WITHOUT KEYLESS OPERATION SYSTEM>
 
Switch positionTerminal numberNormal value
Push (open)1 - 2 The resistance should be 2 ohms or less.
Release1 - 2 No continuity
 
 
 
LIFTGATE LOCK ACTUATOR CHECK
 
Lever positionBattery connectionLever operation
At the "SET" position
  • Connect terminal 2 to negative battery terminal.
  • Connect terminal 3 to positive battery terminal.
Lever moves from "SET" to "OPEN" position.
 
 
 
LIFTGATE LATCH SWITCH CHECK
 
Claw positionTerminal numberNormal value
Unlatch (ON)/ Half-latch (ON)1 - 2 The resistance should be 2 ohms or less.
Full-latch (OFF)1 - 2 No continuity