STEP 2. Using scan tool (M.U.T.-IIISE), check actuator test.
(1) Turn the ignition switch to the "ON" position.
(2) Check the following item in the actuator test. Refer to Actuator Test Reference Table .- Item 4: Evaporative Emission Purge Solenoid ON
(3) Turn the ignition switch to the "LOCK" (OFF) position.
Is the actuator operating properly?
Go to Step 3. Repair or replace it. Then confirm that the malfunction symptom is eliminated.