[Previous][Next]
ACTUATOR TEST REFERENCE TABLE
note*: Continues for 27 minutes. Can be released by pressing the CLEAR key.
M.U.T.-IIISE SCAN TOOL DISPLAYITEM NO.INSPECTION ITEMDRIVE CONTENTSINSPECTION REQUIREMENTNORMAL CONDITION
A/C compressor relay OFF12A/C compressor clutch relayA/C compressor clutch relay turns OFF.Ignition switch: "ON"Sound of operation cannot be heard.
A/C compressor relay ON11A/C compressor clutch relay turns from OFF to ON.Clicks when A/C compressor clutch is driven.
Cooling fan OFF8Radiator fan, A/C condenser fan Stop the fan motor.Ignition switch: "ON"Radiator fan and A/C condenser fan stop.
Cooling fan ON7Drive the fan motor.Radiator fan and A/C condenser fan rotate.
Evaporative emission purge solenoid OFF5Evaporative emission purge solenoidSolenoid valve turns OFF.Ignition switch: "ON"Sound of operation cannot be heard.
Evaporative emission purge solenoid ON4Solenoid valve turns from OFF to ON.Clicks when solenoid valve is driven.
Evaporative emission ventilation solenoid OFF10Evaporative emission ventilation solenoidSolenoid valve turns OFF.Ignition switch: "ON"Sound of operation cannot be heard.
Evaporative emission ventilation solenoid ON9Solenoid valve turns from OFF to ON.Clicks when solenoid valve is driven.
Fuel pump OFF3Fuel pumpStop driving the fuel pump and stop fuel circulationIgnition switch: "ON"Listen near the fuel tank for the sound of fuel pump operation.Sound of operation cannot be heard.
Fuel pump ON2Fuel pump operates and fuel is recirculated.Sound of operation is heard.
Ignition timing 5 BTDC6*Basic ignition timingSet to ignition timing adjustment mode.
  • Engine: idling
  • Connect timing light
5°BTDC
Injector stop1InjectorsSpecified injector is stopped.Engine: warm up, idle. (cut the fuel supply to each injector in turn and check cylinders which don't affect idling)Idle condition is changed by stopping selected cylinder: this can cause an unstable condition and the engine may stall.
Oil feeder control valve OFF14Intake engine oil control valve, Exhaust engine oil control valveIntake engine oil control valve and exhaust engine oil control valve turns OFF.Ignition switch: ONSound of operation cannot be heard.
Oil feeder control valve ON13Switch the intake engine oil control valve and exhaust engine oil control valve from OFF to ON.When the valve is actuated, operating noise is audible.