[Previous][Next]
SOLENOID VALVE CHECK
1. While pressing A in the figure, turn B counterclockwise to unlock the CVT assembly connector, and disconnect the connector.
2. Measure the resistance between the terminals of the applicable solenoid valves and ground.
Standard value:
 
Terminal No.Applicable solenoid valveResistance value Ω
1Line pressure solenoid valve
  • Approximately 5.3 [Fluid temperature: 20°C (68°F)]
  • Approximately 5.9 [Fluid temperature: 50°C (122°F)]
  • Approximately 6.5 [Fluid temperature: 80°C (176°F)]
2Primary pressure solenoid valve
6Low brake solenoid valve
7High clutch and reverse brake solenoid valve
8Lockup solenoid valve
  • Approximately 6.1 [Fluid temperature: 20°C (68°F)]
  • Approximately 6.8 [Fluid temperature: 50°C (122°F)]
  • Approximately 7.5 [Fluid temperature: 80°C (176°F)]
3.
cautionEach solenoid valve cannot be removed or replaced as a single unit.
When the resistance is outside the standard value, replace the valve body assembly (Refer to ).