STEP 1. Using scan tool (M.U.T.-III), check data list item 10: Mass Airflow Sensor.
caution | To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III). |
(1) Connect scan tool (M.U.T.-III). Refer to HOW TO CONNECT THE SCAN TOOL (M.U.T.-III) . (2) Start the engine and run at idle.
(3) Set scan tool (M.U.T.-III) to the data reading mode for item 10, Mass Airflow Sensor.
(4) Warm up the engine to normal operating temperature: 80°C to 95°C (176°F to 203°F).- The standard value during idling should be between 760 and 1,080 millivolts.
- When the engine is revved, the output voltage should increase according to the increase in engine speed.
(5) Turn the ignition switch to the "LOCK" (OFF) position.
Is the sensor operating properly?
It can be assumed that this malfunction is intermittent. Refer to GROUP 00, How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions . Go to Step 2.