[Previous][Next]
Diagnosis Procedure
1.CHECK LVDS CABLE 1
  1. Turn the electric motor switch OFF.
  2. Check the connection status of the LVDS cable connector. (around view monitor control unit side, wire to wire, and front camera side)
Is inspection result normal?
.
Connect the LVDS cable connector correctly.
 
2.CHECK LVDS CABLE 2
  1. Turn the electric motor switch OFF.
  2. Disconnect around view monitor control unit connector and front camera connector.
  3. Check continuity between around view monitor control unit harness connector and front camera harness connector.
    Around view monitor control unitFront cameraContinuity
    ConnectorTerminalsConnectorTerminals
    B8139B841Existed
    402
  4. Check continuity between around view monitor control unit harness connector and ground.
    Around view monitor control unitGroundContinuity
    ConnectorTerminal
    B8139Not existed
Is inspection result normal?
Replace front camera. Refer to Removal and Installation.
Replace LVDS cable.