1.CHECK BRAKE FLUID LEVEL
2.PERFORM DIAGNOSTIC TROUBLE CODE (1)
4.PERFORM DIAGNOSTIC TROUBLE CODE (2)
5.CHECK BRAKE FLUID LEVEL SWITCH
6.PERFORM DIAGNOSTIC TROUBLE CODE (3)
7.CHECK CONNECTOR AND TERMINAL
8.PERFORM DIAGNOSTIC TROUBLE CODE (4)
9.CHECK BRAKE FLUID LEVEL SWITCH CIRCUIT
- Disconnect 12V battery negative terminal.
- Disconnect brake fluid level switch harness connector.
- Disconnect combination meter harness connector.
- Check the continuity between brake fluid level switch harness connector and combination meter harness connector.
Brake fluid level switch | Combination meter | Continuity |
Connector | Terminal | Connector | Terminal |
E63 | 1 | M76*1 M77*2 | 28 | Existed |
*1: With 7 inch information display
*2: With full TFT meter
- Check the continuity between brake fluid level switch harness connector and ground.
Brake fluid level switch | — | Continuity |
Connector | Terminal |
E63 | 1 | Ground | Not existed |
Is the inspection result normal?
. Repair / replace harness or connector. .
10.CHECK BRAKE FLUID LEVEL SWITCH GROUND CIRCUIT
11.CHECK COMBINATION METER
- Connect brake fluid level switch harness connector.
- Connect combination meter harness connector.
- Connect 12V battery negative terminal.
- Check the combination meter. Refer to On Board Diagnosis Function.
Is the inspection result normal?