(1) Disconnect the On Board Charger (OBC)/DC-DC converter connector (B532), and measure at the wiring harness side.
(2) Change the power supply mode of the electric motor switch to ON (READY indicator: OFF).
(3) Measure the voltage between the following terminals.
- Resistance between On Board Charger (OBC)/DC-DC converter connector (No. 3 terminal) and body ground
OK: 1 V or less
Is the check result normal?
Repair the connector(s) or wiring harness.