CHECK ON INSULATION RESISTANCE OF POWER DRIVE UNIT
danger
cautionThe insulation resistance check must be completed within 10 seconds. (Since DC 1,000 V is applied while checking, parts may be damaged if the check continues for 10 seconds or more.)
Required Special Tools:
  • MB991223: Wiring harness set
  • MB992006: Extra fine probe
  • MB992355: Electric insulation tester
1. Remove the power drive unit cover.
2. Remove the service lid on the power drive unit.
3. Disconnect the following cables from the power drive unit.
  • Front motor cable
  • Generator cable
  • Drive battery front cable
  • A/C compressor cable
4. Use the electric insulation tester (Special tool: MB992355) and set it to the 1,000 V range.
5. Measure the insulation resistance between the power drive unit high voltage terminals (10 locations) and power drive unit (body ground).
Standard value: 10 MΩ or more
6. If the measured value is not within the standard value, replace the power drive unit.